如何使用vb6.0写modbusrtu通讯

时间: 2023-07-20 17:05:14 浏览: 83
你可以使用VB6.0调用Windows API函数实现Modbus RTU通信。以下是一个简单的示例代码,可以帮助你入门: ``` Private Declare Sub Sleep Lib "kernel32" (ByVal dwMilliseconds As Long) Private Declare Function CreateFile Lib "kernel32" Alias "CreateFileA" (ByVal lpFileName As String, ByVal dwDesiredAccess As Long, ByVal dwShareMode As Long, lpSecurityAttributes As Any, ByVal dwCreationDisposition As Long, ByVal dwFlagsAndAttributes As Long, ByVal hTemplateFile As Long) As Long Private Declare Function WriteFile Lib "kernel32" (ByVal hFile As Long, lpBuffer As Any, ByVal nNumberOfBytesToWrite As Long, lpNumberOfBytesWritten As Long, lpOverlapped As Any) As Long Private Declare Function ReadFile Lib "kernel32" (ByVal hFile As Long, lpBuffer As Any, ByVal nNumberOfBytesToRead As Long, lpNumberOfBytesRead As Long, lpOverlapped As Any) As Long Private Declare Function CloseHandle Lib "kernel32" (ByVal hObject As Long) As Long Const GENERIC_READ = &H80000000 Const GENERIC_WRITE = &H40000000 Const OPEN_EXISTING = 3 Const FILE_ATTRIBUTE_NORMAL = &H80 Const INVALID_HANDLE_VALUE = -1 Private Function ModbusRTU_Read(ByVal PortName As String, ByVal Address As Byte, ByVal FunctionCode As Byte, ByVal StartAddress As Integer, ByVal NumOfPoints As Integer, ByRef Data() As Byte) As Boolean Dim hCom As Long Dim Buffer() As Byte Dim CRC() As Byte Dim nWritten As Long Dim nRead As Long Dim i As Integer Dim j As Integer Dim k As Integer ' Open the serial port hCom = CreateFile(PortName, GENERIC_READ Or GENERIC_WRITE, 0, ByVal 0&, OPEN_EXISTING, FILE_ATTRIBUTE_NORMAL, 0) If hCom = INVALID_HANDLE_VALUE Then ModbusRTU_Read = False Exit Function End If ' Construct the MODBUS RTU request ReDim Buffer(0 To 7 + NumOfPoints * 2) Buffer(0) = Address Buffer(1) = FunctionCode Buffer(2) = StartAddress \ 256 Buffer(3) = StartAddress Mod 256 Buffer(4) = NumOfPoints \ 256 Buffer(5) = NumOfPoints Mod 256 CRC = ModbusRTU_CRC(Buffer, 0, 6) Buffer(6 + NumOfPoints * 2) = CRC(0) Buffer(7 + NumOfPoints * 2) = CRC(1) ' Send the request If WriteFile(hCom, Buffer(0), UBound(Buffer) + 1, nWritten, ByVal 0&) = 0 Then ModbusRTU_Read = False CloseHandle hCom Exit Function End If ' Wait for response Sleep 10 * (NumOfPoints \ 8 + 1) ' Read the response ReDim Buffer(0 To 7 + NumOfPoints * 2) If ReadFile(hCom, Buffer(0), UBound(Buffer) + 1, nRead, ByVal 0&) = 0 Or nRead <> UBound(Buffer) + 1 Then ModbusRTU_Read = False CloseHandle hCom Exit Function End If ' Verify the response If Buffer(0) <> Address Or Buffer(1) <> FunctionCode Or Buffer(2) <> NumOfPoints * 2 Then ModbusRTU_Read = False CloseHandle hCom Exit Function End If CRC = ModbusRTU_CRC(Buffer, 0, 5 + NumOfPoints * 2) If Buffer(6 + NumOfPoints * 2) <> CRC(0) Or Buffer(7 + NumOfPoints * 2) <> CRC(1) Then ModbusRTU_Read = False CloseHandle hCom Exit Function End If ' Extract the data ReDim Data(0 To NumOfPoints - 1) k = 0 For i = 0 To NumOfPoints - 1 j = 3 + i * 2 Data(i) = Buffer(j) * 256 + Buffer(j + 1) k = k + Data(i) Next i ModbusRTU_Read = True CloseHandle hCom End Function Private Function ModbusRTU_CRC(ByVal Data() As Byte, ByVal StartIndex As Integer, ByVal Count As Integer) As Byte() Dim i As Integer Dim j As Integer Dim Table() As Integer Dim CRC As Integer ' Initialize the CRC table ReDim Table(0 To 255) For i = 0 To 255 CRC = i For j = 0 To 7 If CRC And 1 Then CRC = (CRC \ 2) Xor &HA001 Else CRC = CRC \ 2 End If Next j Table(i) = CRC Next i ' Calculate the CRC CRC = &HFFFF For i = StartIndex To StartIndex + Count - 1 CRC = Table((CRC Xor Data(i)) And &HFF) Xor (CRC \ 256) Next i ' Return the CRC in little-endian order ModbusRTU_CRC = Array(CRC Mod 256, CRC \ 256) End Function ``` 此代码使用Windows API函数打开串口,并构建MODBUS RTU请求。在发送请求后,它等待一段时间,然后读取响应。最后,它提取数据并关闭串口。请注意,此代码仅处理一个功能码-读取多个保持寄存器(功能码03h)。如果您需要执行其他操作,您需要修改代码。

相关推荐

最新推荐

recommend-type

手把手教VB 实现MODBUS RTU通讯

手把手教VB 实现MODBUS RTU通讯 通过VB实现工业通讯MODBUS
recommend-type

三菱FX1Nplc自写MODBUS RTU 从站程序编程实例.pdf

三菱FX1Nplc自写MODBUS RTU 从站程序编程实例,该文档由三菱PLC编程软件直接打印生成的PDF文档,可为自己编程做参考,实际的编程实例可以至http://www.jx-auto.cn/thread-26770-1-1.html江西自动化网下载
recommend-type

杨铮.WINCC与浙大中控不同网段传送数据解决方案MODBUS RTU链接说明.pdf

采用MODBUS RTU方式,摒弃MODBUS TCP IP 方式,因为两台电脑不再一个网段,MODBUS TCP IP不可用,只能采用MODBUS RTU方式。MODBUS TCP IP&lt;——&gt;MODBUS RTU转换设备。
recommend-type

详解S7-1500PLC 实现 Modbus-RTU 通信.docx

以示例项目为例,主要阐述关于SIEMENS S7-1500PLC 实现 Modbus-RTU 通信的配置步骤、程序编写及注意事项
recommend-type

KingSCADA软件MODBUS通讯演示v1.0.pptx

KingSCADA v3.7连接仿真的MODBUS通讯,详细步骤,图文结合,简单易懂,可用于扩展连接大部分PLC的使用。
recommend-type

zigbee-cluster-library-specification

最新的zigbee-cluster-library-specification说明文档。
recommend-type

管理建模和仿真的文件

管理Boualem Benatallah引用此版本:布阿利姆·贝纳塔拉。管理建模和仿真。约瑟夫-傅立叶大学-格勒诺布尔第一大学,1996年。法语。NNT:电话:00345357HAL ID:电话:00345357https://theses.hal.science/tel-003453572008年12月9日提交HAL是一个多学科的开放存取档案馆,用于存放和传播科学研究论文,无论它们是否被公开。论文可以来自法国或国外的教学和研究机构,也可以来自公共或私人研究中心。L’archive ouverte pluridisciplinaire
recommend-type

实现实时数据湖架构:Kafka与Hive集成

![实现实时数据湖架构:Kafka与Hive集成](https://img-blog.csdnimg.cn/img_convert/10eb2e6972b3b6086286fc64c0b3ee41.jpeg) # 1. 实时数据湖架构概述** 实时数据湖是一种现代数据管理架构,它允许企业以低延迟的方式收集、存储和处理大量数据。与传统数据仓库不同,实时数据湖不依赖于预先定义的模式,而是采用灵活的架构,可以处理各种数据类型和格式。这种架构为企业提供了以下优势: - **实时洞察:**实时数据湖允许企业访问最新的数据,从而做出更明智的决策。 - **数据民主化:**实时数据湖使各种利益相关者都可
recommend-type

解释minorization-maximization (MM) algorithm,并给出matlab代码编写的例子

Minorization-maximization (MM) algorithm是一种常用的优化算法,用于求解非凸问题或含有约束的优化问题。该算法的基本思想是通过构造一个凸下界函数来逼近原问题,然后通过求解凸下界函数的最优解来逼近原问题的最优解。具体步骤如下: 1. 初始化参数 $\theta_0$,设 $k=0$; 2. 构造一个凸下界函数 $Q(\theta|\theta_k)$,使其满足 $Q(\theta_k|\theta_k)=f(\theta_k)$; 3. 求解 $Q(\theta|\theta_k)$ 的最优值 $\theta_{k+1}=\arg\min_\theta Q(
recommend-type

JSBSim Reference Manual

JSBSim参考手册,其中包含JSBSim简介,JSBSim配置文件xml的编写语法,编程手册以及一些应用实例等。其中有部分内容还没有写完,估计有生之年很难看到完整版了,但是内容还是很有参考价值的。