写个modbustcp类
时间: 2023-03-19 14:23:22 浏览: 129
modbus tcp例程
好的,以下是一个使用Python实现Modbus TCP通信的示例类:
```python
import socket
class ModbusTCP:
def __init__(self, ip_address, port):
self.ip_address = ip_address
self.port = port
self.socket = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
self.socket.connect((self.ip_address, self.port))
def read_coils(self, start_address, quantity):
# Modbus function code for reading coils is 0x01
function_code = 0x01
# Build Modbus request message
message = bytearray([0x00, 0x01, 0x00, 0x00, 0x00, 0x06, 0x01,
(start_address >> 8) & 0xFF, start_address & 0xFF,
(quantity >> 8) & 0xFF, quantity & 0xFF])
# Send Modbus request message and receive response
response = self._send_message(message, function_code)
# Extract coil states from response and return as list of booleans
coil_states = [bool(response[9 + i//8] & (1 << (i % 8))) for i in range(quantity)]
return coil_states
def write_coil(self, address, value):
# Modbus function code for writing a single coil is 0x05
function_code = 0x05
# Convert value to 0xFF00 or 0x0000
value = 0xFF00 if value else 0x0000
# Build Modbus request message
message = bytearray([0x00, 0x01, 0x00, 0x00, 0x00, 0x06, 0x05,
(address >> 8) & 0xFF, address & 0xFF,
(value >> 8) & 0xFF, value & 0xFF])
# Send Modbus request message and receive response
self._send_message(message, function_code)
def _send_message(self, message, function_code):
# Modbus transaction identifier is just set to 0x00
transaction_id = 0x00
# Modbus protocol identifier is 0x0000 for Modbus TCP
protocol_id = 0x0000
# Length of message is length of message field plus 6 bytes for header
length = len(message) + 6
# Build Modbus TCP header
header = bytearray([transaction_id >> 8, transaction_id & 0xFF,
protocol_id >> 8, protocol_id & 0xFF,
length >> 8, length & 0xFF,
0x00, 0x00,
0x00, 0x00,
function_code])
# Concatenate header and message to form complete Modbus TCP packet
packet = header + message
# Send packet to server and receive response
self.socket.send(packet)
response = self.socket.recv(1024)
# Verify Modbus TCP header
if len(response) < 9:
raise Exception('Invalid Modbus TCP response')
response_transaction_id = (response[0] << 8) | response[1]
response_protocol_id = (response[2] << 8) | response[3]
response_length = (response[4] << 8) | response[5]
response_unit_id = response[6]
response_function_code = response[7]
阅读全文