如何用STM32F103C8T6内置ADC模块进行模数转换
时间: 2023-05-26 08:05:31 浏览: 447
以下是使用STM32F103C8T6内置ADC模块进行模数转换的基本步骤:
1. 配置GPIO引脚为模拟输入:
选用的引脚需要配置为模拟输入模式,具体方法为使用GPIO_Init函数配置对应的GPIO结构体变量的对应位。
2. 配置ADC模块:
- 开启ADC时钟:RCC_APB2PeriphClockCmd(RCC_APB2Periph_ADC1, ENABLE);
- 配置ADC参数:采样率、顺序、通道等参数
typedef struct
{
uint32_t ADC_Mode; /*!< Configures the ADC to operate in independent or dual mode.
This parameter can be a value of @ref ADC_mode */
FunctionalState ADC_DualMode; /*!< Configures the ADC to operate in independent or dual mode.
This parameter can be set either to ENABLE or DISABLE. */
uint32_t ADC_DataAlign; /*!< Specifies whether the ADC data alignment is left or right.
This parameter can be a value of @ref ADC_data_align */
uint32_t ADC_Resolution; /*!< Configures the ADC resolution dual mode.
This parameter can be ADC_Resolution_12b, ADC_Resolution_10b,
ADC_Resolution_8b or ADC_Resolution_6b. */
uint32_t ADC_ExternalTrigConv; /*!< Configures the ADC external trigger for injected channels.
This parameter can be a value of @ref ADC_external_trigger_sources_for_jInjected_channels_conversion */
uint32_t ADC_ExternalTrigConvEdge; /*!< Configures the ADC external trigger edge for injected channels.
This parameter can be a value of
@ref ADC_external_trigger_edge_for_JInjected_channels_conversion */
uint32_t ADC_NbrOfConversion; /*!< Specifies the number of ADC conversions that will be done using
the sequencer for regular channel group.
This parameter must be a number between Min_Data = 1 and Max_Data = 16. */
}ADC_InitTypeDef;
3. 启动ADC模块:
ADC_Cmd(ADC1,ENABLE);
4. 开始模数转换:
- ADC_Rank需要配置位于第几个排通道,可以配置为0-15,代表第1-16个通道
- ADC_SampleTime代表每个转换的采样时间长度,越大可能会减少噪声,但也会增加转换时间
- ADC_ExternalTrigConv代表启用外部触发转换功能
ADC_RegularChannelConfig(ADC1,ADC_Channel_0,ADC_Rank_1,ADC_SampleTime_55Cycles5);
5. 等待模数转换完成:
while(!ADC_GetFlagStatus(ADC1,ADC_FLAG_EOC));
6. 取出模数转换结果:
result=ADC_GetConversionValue(ADC1);
有关函数的详细使用请参考STM32F10x_StdPeriph_Driver库中的ADC部分。