Error: CRC error at ModbusRTU._onReceive (/usr/local/lib/node_modules/@frangoteam/fuxa/node_modules/modbus-serial/index.js:356:14) at RTUBufferedPort.emit (events.js:198:13) at RTUBufferedPort._emitData (/usr/local/lib/node_modules/@frangoteam/fuxa/node_modules/modbus-serial/ports/rtubufferedport.js:161:14) at SerialPort.onData (/usr/local/lib/node_modules/@frangoteam/fuxa/node_modules/modbus-serial/ports/rtubufferedport.js:127:30) at SerialPort.emit (events.js:198:13) at addChunk (_stream_readable.js:288:12) at readableAddChunk (_stream_readable.js:269:11) at SerialPort.Readable.push (_stream_readable.js:224:10) at port.read.then (/usr/local/lib/node_modules/@frangoteam/fuxa/node_modules/@serialport/stream/dist/index.js:202:18)
时间: 2023-08-02 14:11:48 浏览: 491
这个错误是一个CRC校验错误,它通常出现在Modbus RTU通信中。CRC校验是一种用于检查通信中数据完整性的技术,如果接收到的数据的CRC校验码与发送方计算的CRC校验码不匹配,就会发生这个错误。需要检查通信的物理连接、波特率设置、数据格式等参数是否正确,并确保发送方和接收方使用相同的CRC校验算法。
相关问题
2023-06-09T03:39:57.576Z [ERR] '会展7#柜泵站' _readMemory error! Error: Data length error, expected 6 got 1 Error: CRC error at ModbusRTU._onReceive (/usr/local/lib/node_modules/@frangoteam/fuxa/node_modules/modbus-serial/index.js:356:14) at SerialPort.emit (events.js:198:13) at addChunk (_stream_readable.js:288:12) at readableAddChunk (_stream_readable.js:269:11) at SerialPort.Readable.push (_stream_readable.js:224:10) at port.read.then (/usr/local/lib/node_modules/@frangoteam/fuxa/node_modules/@serialport/stream/dist/index.js:202:18) 2023-06-09T03:39:57.988Z [ERR] '会展7#柜泵站' _readMemory error! Error: CRC error
这个错误也与 Modbus 通信有关,看起来是一个 CRC 错误。你需要检查通信设置和硬件设备是否正确配置,并确认你的代码是否正确地解析 Modbus 数据。你可以尝试重新启动设备和计算机来解决问题,或者调整通信设置以提高通信稳定性。如果问题仍然存在,你可能需要检查硬件设备或者 Modbus 通信协议是否存在问题。
Error: Modbus exception 2: Illegal data address (register not supported by device) at ModbusRTU._onReceive (/usr/lib/node_modules/@frangoteam/fuxa/node_modules/modbus-serial/index.js:370:21) at RTUBufferedPort.emit (node:events:513:28) at RTUBufferedPort._emitData (/usr/lib/node_modules/@frangoteam/fuxa/node_modules/modbus-serial/ports/rtubufferedport.js:161:14) at SerialPort.onData (/usr/lib/node_modules/@frangoteam/fuxa/node_modules/modbus-serial/ports/rtubufferedport.js:131:30) at SerialPort.emit (node:events:513:28) at addChunk (node:internal/streams/readable:315:12) at readableAddChunk (node:internal/streams/readable:289:9) at SerialPort.Readable.push (node:internal/streams/readable:228:10) at /usr/lib/node_modules/@frangoteam/fuxa/node_modules/@serialport/stream/dist/index.js:202:18 { modbusCode: 2
根据提供的错误信息,看起来您正在使用的是Modbus-serial库进行Modbus通信,并且出现了"Modbus异常2: 非法的数据地址(设备不支持的寄存器)"的错误。
这个错误通常表示您正在尝试访问设备不支持的寄存器地址。可能原因包括:
1. 寄存器地址超出设备支持的范围。
2. 设备不支持您尝试访问的特定寄存器类型。
要解决这个问题,您可以参考以下建议:
1. 确认寄存器地址是否正确:检查您在代码中使用的寄存器地址是否与设备文档或规范中指定的兼容。确保您正在使用正确的寄存器类型和地址格式。
2. 检查设备支持的寄存器范围:查阅设备文档或规范,了解设备支持的寄存器类型和地址范围。确保您的代码中使用的寄存器地址在设备支持的范围内。
3. 联系设备供应商或制造商:如果问题仍然存在,建议您联系设备供应商或制造商的技术支持团队,以获取更具体的帮助和指导。他们可能会提供特定于设备的解决方案或建议。
请注意,由于我是一个AI助手,无法直接解决您的编程问题。提供的建议仅供参考,请根据实际情况进行调试和排除故障。
阅读全文