PECL DC CHARACTERISTICS
(1)
(V
CC
= 5 V; V
EE
= 0 V)
(2)
NECL DC CHARACTERISTICS
(1)
(V
CC
= 0 V; V
EE
= 5 V)
(2)
SN65EL11
www.ti.com
............................................................................................................................................................................................ SLLS920 – DECEMBER 2008
– 40 ° C 25 ° C 85 ° C
PARAMETER UNIT
MIN TYP MAX MIN TYP MAX MIN TYP MAX
I
CC
Power-supply current 18 26 21 26 23 26 mA
V
OH
Output HIGH voltage
(3)
3915 4120 3915 4000 4120 3915 4120 mV
V
OL
Output LOW voltage
(3)
3170 3380 3170 3288 3380 3170 3380 mV
V
IH
Input HIGH voltage (single-ended) 3835 4120 3835 4120 3835 4120 mV
V
IL
Input LOW voltage (single-ended) 3190 3525 3190 3525 3190 3525 mV
Input HIGH voltage, common-mode
V
IHCMR
2.5 4.6 2.5 4.6 2.5 4.6 V
range (differential)
(4)
I
IH
Input HIGH current 150 150 150 µ A
I
IL
Input LOW current 0.5 0.5 0.5 µ A
(1) The device meets these specifications after thermal equilibrium has been established when mounted in a test socket or printed-circuit
board with maintained transverse airflow greater than 500 lfpm (2.54 m/s). Electrical parameters are assured only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
(2) Input and output parameters vary 1:1 with V
CC
. V
EE
can vary +0.25 V / – 0.5 V.
(3) Outputs are terminated through a 50- Ω resistor to V
CC
– 2 V.
(4) V
IHCMR
min varies 1:1 with V
EE
; V
IHCMR
max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the more-positive side of the
differential input signal. Normal operation is obtained if the HIGH level falls within the specified range and the peak-to-peak voltage lies
between V
PP
min and 1 V.
PARAMETER – 40 ° C 25 ° C 85 ° C
UNIT
MIN TYP MAX MIN TYP MAX MIN TYP MAX
I
EE
Power-supply current 19 26 21 26 23 26 mA
V
OH
Output HIGH voltage
(3)
– 1085 – 880 – 1025 – 995 – 880 – 1025 – 880 mV
V
OL
Output LOW voltage
(3)
– 1830 – 1620 – 1810 – 1712 – 1620 – 1810 – 1620 mV
V
IH
Input HIGH voltage (single-ended) – 1165 – 880 – 1165 – 880 – 1165 – 880 mV
V
IL
Input LOW voltage (single-ended) – 1810 – 1475 – 1810 – 1475 – 1810 – 1475 mV
Input HIGH voltage, common-mode
V
IHCMR
– 2.5 – 0.4 – 2.5 – 0.4 – 2.5 – 0.4 V
range (differential)
(4)
I
IH
Input HIGH current 150 150 150 µ A
I
IL
Input LOW current 0.5 0.5 0.5 µ A
(1) The device meets these specifications after thermal equilibrium has been established when mounted in a test socket or printed-circuit
board with maintained transverse airflow greater than 500 lfpm (2.54 m/s). Electrical parameters are assured only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
(2) Input and output parameters vary 1:1 with V
CC
. V
EE
can vary +0.25 V / – 0.5 V.
(3) Outputs are terminated through a 50- Ω resistor to V
CC
– 2 V.
(4) V
IHCMR
min varies 1:1 with V
EE
; V
IHCMR
max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the more-positive side of the
differential input signal. Normal operation is obtained if the HIGH level falls within the specified range and the peak-to-peak voltage lies
between V
PP
min and 1 V.
Copyright © 2008, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Link(s): SN65EL11