TOSEI ENGINEERING CORP.
For post process
Electric Micrometer
Control Unit
Operations Manual
■Precaution
Please observe the following articles to ensure the safe use of this
equipment.
[Warning]
1. Please avoid using equipment in out-of-range temperature, humidity, water droplets,
dust, smoke, sunlight, extreme shock, high vibration, and corrosive gases.,
Equipment is to susceptible to fall, may cause problems to the equipment. There
is a risk of electric shock due to the failure of equipment.
2. Regarding stand mounting of the equipment, please use a stand enough to withstand
the weight of the equipment. Also, please ensure sufficient stability of the stand.
There is a possibility of collapse of the frame, and may cause problems for the
equipment.
3. Power cables; please connect to specific rated voltage terminals. Due to failure,
electric shock or fire may result.
4. Please make sure the wire is grounded. There is a risk of electric shock or failure,
when leakage occurs.
5. Communication cables may carry hazardous currents and surge. To avoid electric
shock, when moving equipment or equipment installation with other connection
devices, please work in a state of all power sources switched off and disconnection
of power cable from the terminal.
6. Please do not pull or trample over connection cable that connects the power source
and equipment. Also, please do not attempt to use the connection cable and the power
cable that are damaged. There is a risk of serious injury or death from electric
shock as connection cable and power cable as cables carry dangerous currents.
7. Please do not insert conductive material such as a piece of metal in particular or
foreign matter into electrical outlets of the equipment. There is a risk of serious
injury from electric shock and fire due to negligence.
[Precaution]
1. Please do not use the power cord while it is in coiled condition.
2. Please make sure to turn off the power to the device when connecting or disconnecting
the cable connection between the device and the power supply source.
[Disclaimer of usage outside Japan]
If the instrument is taken out of Japan, please let us know in advance as it might infringe
local regulations. If equipment is moved out of the Japan without notice, if an accident
occurs, the Company will not be held responsible.
[Notice]
1. This system is composed of precision electronic components and mechanisms.Please
do not move in rough fashion and disassemble by means of rough handling.
2. Please choose site with little dirt, dust, water droplets, smoke, vibration for
installation.
[Installation guide]
1. The control unit power supply line, the power line, connecting wire I / O, measuring
head cable, should not be closer than 200mm in proximity.
2. If wiring is done, we recommend the use of a wiring duct.
3. Please do not house the measuring head cable in the same duct with other wirings.
4. Measuring head that can be pre-recession regardless of the status of the output of the
instrument. At the time of adjustment, kindly pay attention to retract release.
■Specification
10~90% R.H.(No condensation)
1s、1500Vp-p(Tested by noise simulator)
JIS B7536 Compliance (AC1000V、1 Minute)
Front panel:IP55 rating
Rear panel:IP20 rating(Non-waterproof)
0.53kg
(Stand mounted approx. 1.00kg)
121x99x51mm (W x H x D)
(Stand mounted 164.5x126.5x78.7mm)
±50m、±100m、±500m、±800m、
±2000m、±3000m、±5000m
Input:4、Output:8
(+Common、-Common Share/Monitor feature
・6 basic types of gage with arithmetic
function
(G1,G2,G1+G2,G1-G2,(G1+G2)/2,(G2-G2)/2)
・Smoothing function
・Ranking(3 Rank、5 Rank)
■Input-output circuitry
◆I/O Port
Input:DC24V 7.2mA(TYP.)
Output:DC24V less than 40mA
Connector:D-sub15pin,#4-40
Cable:6m Shielded cable Outer DiameterΦ9.6