6
TS3USB221
ZHCSJ98J –NOVEMBER 2006–REVISED JANUARY 2019
www.ti.com.cn
Copyright © 2006–2019, Texas Instruments Incorporated
(1) For Maximum or Minimum conditions, use the appropriate value specified under Electrical Characteristics for the applicable device type.
6.6 Dynamic Electrical Characteristics, V
CC
= 3.3 V ± 10%
over operating range, T
A
= –40°C to 85°C, V
CC
= 3.3 V ± 10%, GND = 0 V
PARAMETER TEST CONDITIONS TYP
(1)
UNIT
X
TALK
Crosstalk R
L
= 50 Ω, f = 250 MHz –40 dB
O
IRR
OFF isolation R
L
= 50 Ω, f = 250 MHz –41 dB
BW Bandwidth (–3 dB) R
L
= 50 Ω 1.1 GHz
(1) For Maximum or Minimum conditions, use the appropriate value specified under Electrical Characteristics for the applicable device type.
6.7 Dynamic Electrical Characteristics, V
CC
= 2.5 V ± 10%
over operating range, T
A
= –40°C to 85°C, V
CC
= 2.5 V ± 10%, GND = 0 V
PARAMETER TEST CONDITIONS TYP
(1)
UNIT
X
TALK
Crosstalk R
L
= 50 Ω, f = 250 MHz –39 dB
O
IRR
OFF isolation R
L
= 50 Ω, f = 250 MHz –40 dB
BW Bandwidth (–3 dB) R
L
= 50 Ω 1.1 GHz
(1) For Maximum or Minimum conditions, use the appropriate value specified under Electrical Characteristics for the applicable device type.
(2) Specified by design
(3) The bus switch contributes no propagational delay other than the RC delay of the on resistance of the switch and the load capacitance.
The time constant for the switch alone is of the order of 0.25 ns for 10-pF load. This time constant adds very little propagational delay to
the system because it is much smaller than the rise/fall times of typical driving signals. Propagational delay of the bus switch, when used
in a system, is determined by the driving circuit on the driving side of the switch and its interactions with the load on the driven side.
6.8 Switching Characteristics, V
CC
= 3.3 V ± 10%
over operating range, T
A
= –40°C to 85°C, V
CC
= 3.3 V ± 10%, GND = 0 V
PARAMETER MIN TYP
(1)
MAX UNIT
t
pd
Propagation delay
(2) (3)
0.25 ns
t
ON
Line enable time
S to D, nD 30
ns
OE to D, nD 17
t
OFF
Line disable time
S to D, nD 12
ns
OE to D, nD 10
t
SK(O)
Output skew between center port to any other port
(2)
0.1 0.2 ns
t
SK(P)
Skew between opposite transitions of the same output (t
PHL
– t
PLH
)
(2)
0.1 0.2 ns
(1) For Maximum or Minimum conditions, use the appropriate value specified under Electrical Characteristics for the applicable device type.
(2) Specified by design
(3) The bus switch contributes no propagational delay other than the RC delay of the on resistance of the switch and the load capacitance.
The time constant for the switch alone is of the order of 0.25 ns for 10-pF load. The time constraint adds very little propagational delay
to the system because it is much smaller than the rise and fall times of typical driving signals. Propagational delay of the bus switch,
when used in a system, is determined by the driving circuit on the driving side of the switch and its interactions with the load on the
driven side.
6.9 Switching Characteristics, V
CC
= 2.5 V ± 10%
over operating range, T
A
= –40°C to 85°C, V
CC
= 2.5 V ± 10%, GND = 0 V
PARAMETER MIN TYP
(1)
MAX UNIT
t
pd
Propagation delay
(2) (3)
0.25 ns
t
ON
Line enable time
S to D, nD 50
ns
OE to D, nD 32
t
OFF
Line disable time
S to D, nD 23
ns
OE to D, nD 12
t
SK(O)
Output skew between center port to any other port
(2)
0.1 0.2 ns
t
SK(P)
Skew between opposite transitions of the same output (t
PHL
– t
PLH
)
(2)
0.1 0.2 ns