ZscMatrix [out, retval] Type: VARIANT* Value; [Property (get)];
'value = ZscMatrix ' -- Complex array of Zsc matrix at bus. Column by column.
Zsc1 [out, retval] Type: VARIANT* Value; [Property (get)];
'value = Zsc1 ' -- Complex Positive-Sequence short circuit impedance at bus..
Zsc0 [out, retval] Type: VARIANT* Value; [Property (get)];
'value = Zsc0 ' -- Complex Zero-Sequence short circuit impedance at bus.
ZscRefresh [out, retval] Type: VARIANT_BOOL* Value; [Method];
' ZscRefresh(arg list) ' -- Recomputes Zsc for active bus for present circuit configuration.
YscMatrix [out, retval] Type: VARIANT* Value; [Property (get)];
'value = YscMatrix ' -- Complex array of Ysc matrix at bus. Column by column.
Coorddefined [out, retval] Type: VARIANT_BOOL* Value; [Property (get)];
'value = Coorddefined ' -- False=0 else True. Indicates whether a coordinate has been defined for this bus
x [out, retval] Type: double* Value; [Property (get)];
'value = x ' -- X Coordinate for bus (double
x [in] Type: double Value; [Property (put)];
' x = value' -- X Coordinate for bus (double
y [out, retval] Type: double* Value; [Property (get)];
'value = y ' -- Y coordinate for bus(double
y [in] Type: double Value; [Property (put)];
' y = value' -- Y coordinate for bus(double
Distance [out, retval] Type: double* Value; [Property (get)];
'value = Distance ' -- Distance from energymeter (if non-zero
GetUniqueNodeNumber [in] Type: long StartNumber, [out, retval] Type: long* Value; [Method];
' GetUniqueNodeNumber(arg list) ' -- Returns a unique node number at the active bus to avoid node
collisions and adds it to the node list for the bus.
CplxSeqVoltages [out, retval] Type: VARIANT* Value; [Property (get)];
'value = CplxSeqVoltages ' -- Complex Double array of Sequence Voltages (0, 1, 2
Lambda [out, retval] Type: double* Value; [Property (get)];
'value = Lambda ' -- Accumulated failure rate downstream from this bus; faults per year
N_interrupts [out, retval] Type: double* Value; [Property (get)];
'value = N_interrupts ' -- Number of interruptions this bus per year
Int_Duration [out, retval] Type: double* Value; [Property (get)];
'value = Int_Duration ' -- Average interruption duration, hr.
Cust_Interrupts [out, retval] Type: double* Value; [Property (get)];
'value = Cust_Interrupts ' -- Annual number of customer-interruptions from this bus
Cust_Duration [out, retval] Type: double* Value; [Property (get)];
'value = Cust_Duration ' -- Accumulated customer outage durations
N_Customers [out, retval] Type: long* Value; [Property (get)];
'value = N_Customers ' -- Total numbers of customers served downline from this bus
VLL [out, retval] Type: VARIANT* Value; [Property (get)];
'value = VLL ' -- For 2- and 3-phase buses, returns variant array of complex numbers represetin L-L
voltages in volts. Returns -1.0 for 1-phase bus. If more than 3 phases, returns only first 3.