3 Normative references
This clause of part 1 is applicable except as follows:
Addition:
IEC 60617-2:1996,Graphical symbols for diagrams – Part 2: Symbol elements, qualifying
symbols and other symbols having general application
4 General
This clause of part 1 is applicable, except as follows:
Addition:
Accessories to this standard are suggested for modes 1, 2 and 3, cases A to C. The socket
outlets and plugs covered by this standard shall be used only in mode 3.
5 Ratings
This clause of part 1 is applicable except as follows:
5.1 Replacement:
Rated operating voltage:
0 to 30 V (signal or control purposes only);
200 - 250 V a.c.
380 - 480 V a.c.
5.2 Replacement:
2 A (signal or control purposes only) 16 A single and three-phase
20 A single and three-phase
30/32 A single and three-phase
60/63 A single and three-phase
70 A single phase, only
NOTE In the following countries the branch circuit overcurrent protection device is based upon 125 % of the
accessory rating: USA.
6 Connection between the power supply and the electric vehicle
This clause of part 1 is applicable except as follows: