20 ABB machinery drives ACS355 | Catalog
Options
Selecting options
The options shown in the table are available within the
ACS355 range. The ordering code, which is shown in the
second column, replaces the XXXX in the type designation
above. You can order as many options as required, simply by
extending the code as necessary.
= standard
= product variant
= option, external
- = not available
*)
= To be ordered as a separate item.
**)
= Available in selected countries.
1)
External options not available in IP66/IP67/UL Type 4X
protection class.
Options Ordering
code
Description Model Availability
IP20
drive
IP66/67
drive
Protection class
*)
NEMA 1/UL type 1 (R0, R1, R2) MUL1-R1 -
*)
NEMA 1/UL type 1 (R3) MUL1-R3 -
*)
NEMA 1/UL type 1 (R4) MUL1-R4 -
B063 IP66/IP67/UL type 4X enclosure -
Control panel
(choose one option only)
J400 Assistant control panel ACS-CP-A
J404 Basic control panel ACS-CP-C -
Panel mounting kit
*)
Panel mounting kit ACS/H-CP-EXT -
*)
Panel holder mounting kit OPMP-01 -
Potentiometer
J402 Potentiometer MPOT-01
-
Fieldbus
(choose one option only)
K451 DeviceNet
TM
FDNA-01
K452 LonWorks
®
FLON-01
K454 PROFIBUS DP FPBA-01
K457 CANopen
®
FCAN-01
K458 Modbus RTU FMBA-01
K462 ControlNet
TM
FCNA-01
K466
1 port EtherNet/IP
TM
, Modbus TCP,
PROFINET IO
FENA-01
K469 EtherCAT
®
FECA-01
*)
RS-485/Modbus FRSA-00
K470 Ether ner PowerLink FEPL-02
K473
1 port EtherNet/IP
TM
, Modbus TCP,
PROFINET IO
FENA-11
K475
2 port EtherNet/IP
TM
, Modbus TCP,
PROFINET IO
FENA-21
*)
20 pack PROFIBUS DP for machinery drives FPBA-01-M
*)
20 pack CANopen for machinery drives FCAN-01-M
Extension modules
(choose one option only)
L502 Speed encoder module MTAC-01
-
L511 Relay output module MREL-01
-
G406 Auxiliary power extension module MPOW-01
-
Remote monitoring
*)
Remote monitoring adapter SREA-01
3AUA0000094517 Remote monitoring adapter NETA-21
High protection class
options
H376 Cable gland kit (IP66/IP67/UL Type 4X) -
F278 Input switch kit (factory installed variant) -
Pressure compensation
C169 Pressure compensation valve -
Tools
*)
FlashDrop tool MFDT-01
*)
DriveWindow Light DriveWindow Light
P924
**)
PLC and AC drive starter kit
External options
*)
Input chokes
1)
*)
EMC filters
1)
*)
Braking resistors
1)
*)
Output chokes
1)
ACS355 - 0XX - 0XAX - X + XXXX
8 ABB machinery drives ACS355 | Catalog
Ratings and types
Type designation
This is the unique reference number (shown above and in
column 4, right) that clearly identifies your drive by current
rating and frame size. Once the drive’s type designation has
been selected, the frame size (column 5) can be used to
determine the drive dimensions, shown on the next page.
Voltages
ACS355 is available in two voltage ranges:
2 = 200 to 240 V
4 = 380 to 480 V
Insert either “2” or “4”, depending on your chosen
construction, current rating, voltage, and option and variant
codes into the type designation shown above.
Current rating
Current rating represents the rated continuous drive output
current inside the drive specification. Motor power stated in
the table below states the typical motor power.
ACS355 - 03E - 02A4 - 2 + N830
Options and variant code
This code states the factory installed or delivered HW and
SW variants or optional equipment attached to the drive. See
pages 14 - 26 for details.
Construction
“01E” within the type designation (shown above) varies
depending on the drive phase and EMC filtering. Choose
below the one you need.
01 = 1-phase
03 = 3-phase
E = EMC filter connected, 50 Hz frequency
U = EMC filter disconnected, 60 Hz frequency
(In case the lter is required it can easily be connected)
Ratings IP20/UL Open type/
NEMA 1 option
Type designation Frame
size
IP20
Frame
size
IP66
P
N
[kW]
P
N
[hp]
I
2N
[A]
1-phase AC supply, 200 to 240 V +B063
0.37 0.5 2.4 ACS355-01X-02A4-2 R0 -
0.75 1.0 4.7 ACS355-01X-04A7-2 R1 -
1.1 1.5 6.7 ACS355-01X-06A7-2 R1 -
1.5 2.0 7.5 ACS355-01X-07A5-2 R2 -
2.2 3.0 9.8 ACS355-01X-09A8-2 R2 -
3-phase AC supply, 200 to 240 V +B063
0.37 0.5 2.4 ACS355-03X-02A4-2 R0 R1
0.55 0.75 3.5 ACS355-03X-03A5-2 R0 R1
0.75 1.0 4.7 ACS355-03X-04A7-2 R1 R1
1.1 1.5 6.7 ACS355-03X-06A7-2 R1 R1
1.5 2.0 7.5 ACS355-03X-07A5-2 R1 R1
2.2 3.0 9.8 ACS355-03X-09A8-2 R2 R3
3.0 3.0 13.3 ACS355-03X-13A3-2 R2 R3
4.0 5.0 17.6 ACS355-03X-17A6-2 R2 R3
5.5 7.5 24.4 ACS355-03X-24A4-2 R3 -
7.5 10.0 31.0 ACS355-03X-31A0-2 R4 -
11.0 15.0 46.2 ACS355-03X-46A2-2 R4 -
3-phase AC supply, 380 to 480 V +B063
0.37 0.5 1.2 ACS355-03X-01A2-4 R0 R1
0.55 0.75 1.9 ACS355-03X-01A9-4 R0 R1
0.75 1.0 2.4 ACS355-03X-02A4-4 R1 R1
1.1 1.5 3.3 ACS355-03X-03A3-4 R1 R1
1.5 2.0 4.1 ACS355-03X-04A1-4 R1 R1
2.2 3.0 5.6 ACS355-03X-05A6-4 R1 R1
3.0 3.0 7.3 ACS355-03X-07A3-4 R1 R1
4.0 5.0 8.8 ACS355-03X-08A8-4 R1 R1
5.5 7.5 12.5 ACS355-03X-12A5-4 R3 R3
7.5 10.0 15.6 ACS355-03X-15A6-4 R3 R3
11.0 15.0 23.1 ACS355-03X-23A1-4 R3 -
15.0 20.0 31.0 ACS355-03X-31A0-4 R4 -
18.5 25.0 38.0 ACS355-03X-38A0-4 R4 -
22.0 30.0 44.0 ACS355-03X-44A0-4 R4 -
X within the type designation stands for E or U.
P
N
for kW = Typical motor power in 400 V at normal use
P
N
for hp = Typical motor power in 460 V at normal use
I
2N
for A = Continuous rms current. 50% overload is allowed
for one minute in ten minutes.
P
N
[kW]
P
N
[hp]
I
2N
[A]
1-phase AC supply, 200 to 240 V
0.37 0.5 2.4
0.75 1.0 4.7
1.1 1.5 6.7
1.5 2.0 7.5
2.2 3.0 9.8
3-phase AC supply, 200 to 240 V
0.37 0.5 2.4
0.55 0.75 3.5
0.75 1.0 4.7
1.1 1.5 6.7
1.5 2.0 7.5
2.2 3.0 9.8
3.0 3.0 13.3
4.0 5.0 17.6
5.5 7.5 24.4
7.5 10.0 31.0
11.0 15.0 46.2
3-phase AC supply, 380 to 480 V
0.37 0.5 1.2
0.55 0.75 1.9
0.75 1.0 2.4
1.1 1.5 3.3
1.5 2.0 4.1
2.2 3.0 5.6
3.0 3.0 7.3
4.0 5.0 8.8
5.5 7.5 12.5
7.5 10.0 15.6
11.0 15.0 23.1
15.0 20.0 31.0
18.5 25.0 38.0
22.0 30.0 44.0
8 ABB machinery drives ACS355 | Catalog
Ratings and types
Type designation
This is the unique reference number (shown above and in
column 4, right) that clearly identifies your drive by current
rating and frame size. Once the drive’s type designation has
been selected, the frame size (column 5) can be used to
determine the drive dimensions, shown on the next page.
Voltages
ACS355 is available in two voltage ranges:
2 = 200 to 240 V
4 = 380 to 480 V
Insert either “2” or “4”, depending on your chosen
construction, current rating, voltage, and option and variant
codes into the type designation shown above.
Current rating
Current rating represents the rated continuous drive output
current inside the drive specification. Motor power stated in
the table below states the typical motor power.
ACS355 - 03E - 02A4 - 2 + N830
Options and variant code
This code states the factory installed or delivered HW and
SW variants or optional equipment attached to the drive. See
pages 14 - 26 for details.
Construction
“01E” within the type designation (shown above) varies
depending on the drive phase and EMC filtering. Choose
below the one you need.
01 = 1-phase
03 = 3-phase
E = EMC filter connected, 50 Hz frequency
U = EMC filter disconnected, 60 Hz frequency
(In case the lter is required it can easily be connected)
Ratings IP20/UL Open type/
NEMA 1 option
Type designation Frame
size
IP20
Frame
size
IP66
P
N
[kW]
P
N
[hp]
I
2N
[A]
1-phase AC supply, 200 to 240 V +B063
0.37 0.5 2.4 ACS355-01X-02A4-2 R0 -
0.75 1.0 4.7 ACS355-01X-04A7-2 R1 -
1.1 1.5 6.7 ACS355-01X-06A7-2 R1 -
1.5 2.0 7.5 ACS355-01X-07A5-2 R2 -
2.2 3.0 9.8 ACS355-01X-09A8-2 R2 -
3-phase AC supply, 200 to 240 V +B063
0.37 0.5 2.4 ACS355-03X-02A4-2 R0 R1
0.55 0.75 3.5 ACS355-03X-03A5-2 R0 R1
0.75 1.0 4.7 ACS355-03X-04A7-2 R1 R1
1.1 1.5 6.7 ACS355-03X-06A7-2 R1 R1
1.5 2.0 7.5 ACS355-03X-07A5-2 R1 R1
2.2 3.0 9.8 ACS355-03X-09A8-2 R2 R3
3.0 3.0 13.3 ACS355-03X-13A3-2 R2 R3
4.0 5.0 17.6 ACS355-03X-17A6-2 R2 R3
5.5 7.5 24.4 ACS355-03X-24A4-2 R3 -
7.5 10.0 31.0 ACS355-03X-31A0-2 R4 -
11.0 15.0 46.2 ACS355-03X-46A2-2 R4 -
3-phase AC supply, 380 to 480 V +B063
0.37 0.5 1.2 ACS355-03X-01A2-4 R0 R1
0.55 0.75 1.9 ACS355-03X-01A9-4 R0 R1
0.75 1.0 2.4 ACS355-03X-02A4-4 R1 R1
1.1 1.5 3.3 ACS355-03X-03A3-4 R1 R1
1.5 2.0 4.1 ACS355-03X-04A1-4 R1 R1
2.2 3.0 5.6 ACS355-03X-05A6-4 R1 R1
3.0 3.0 7.3 ACS355-03X-07A3-4 R1 R1
4.0 5.0 8.8 ACS355-03X-08A8-4 R1 R1
5.5 7.5 12.5 ACS355-03X-12A5-4 R3 R3
7.5 10.0 15.6 ACS355-03X-15A6-4 R3 R3
11.0 15.0 23.1 ACS355-03X-23A1-4 R3 -
15.0 20.0 31.0 ACS355-03X-31A0-4 R4 -
18.5 25.0 38.0 ACS355-03X-38A0-4 R4 -
22.0 30.0 44.0 ACS355-03X-44A0-4 R4 -
X within the type designation stands for E or U.
P
N
for kW = Typical motor power in 400 V at normal use
P
N
for hp = Typical motor power in 460 V at normal use
I
2N
for A = Continuous rms current. 50% overload is allowed
for one minute in ten minutes.
ACS355-01X-02A4-2
ACS355-01X-04A7-2
ACS355-01X-06A7-2
ACS355-01X-07A5-2
ACS355-01X-09A8-2
ACS355-03X-02A4-2
ACS355-03X-03A5-2
ACS355-03X-04A7-2
ACS355-03X-06A7-2
ACS355-03X-07A5-2
ACS355-03X-09A8-2
ACS355-03X-13A3-2
ACS355-03X-17A6-2
ACS355-03X-24A4-2
ACS355-03X-31A0-2
ACS355-03X-46A2-2
ACS355-03X-01A2-4
ACS355-03X-01A9-4
ACS355-03X-02A4-4
ACS355-03X-03A3-4
ACS355-03X-04A1-4
ACS355-03X-05A6-4
ACS355-03X-07A3-4
ACS355-03X-08A8-4
ACS355-03X-12A5-4
ACS355-03X-15A6-4
ACS355-03X-23A1-4
ACS355-03X-31A0-4
ACS355-03X-38A0-4
ACS355-03X-44A0-4