S
IMATIC NET
S
7-CPs for PROFIBUS
Manual Part B3
CP 443-5 Basic
6GK7 443-5FX02-0XE0 Version 1 and higher (firmware version V4.0 and higher)
for SIMATIC S7-400 / S7-400H
PROFIBUS interface
(9-pin D-sub female
connector)
Mode selector
Status and fault LEDs
Notes on the Product
B3-2
CP 443-5 Basic for PROFIBUS / Manual Part B3
Release 11/2002
C79000-G8976-C161-04
Notes on the Product
Note
All notes in the product information bulletin, which is supplied with this product,
are valid and must be observed.
Compatibility with the Previous Version
Note
Make sure that you read the information regarding extended functionality and
restrictions in Chapter 6 of this manual!
B3-3
CP 443-5 Basic for PROFIBUS / Manual Part B3
Release 11/2002
C79000-G8976-C161-04
Contents
Contents - Part A
PROFIBUS CPs - General Information See General Part. . . . . . . . . . . . . .
Note
Please remember that Part A of the manual also belongs to the description of the
CP. Among other things, it contains explanations of the safety notices, references,
and general information that applies to all S7 CPs for PROFIBUS.
You can also download this general part from the Internet:
http://www4.ad.siemens.de/view/cs/de/8774037
Contents - Part B3
1 Properties / Services B3-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Requirements for Use B3-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 Use with the Current CPU Types B3-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Converting older Systems B3-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Installation and Commissioning B3-9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Displays and Mode Selector B3-10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Performance Data B3-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1 Supported Transmission Rates B3-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2 Data of S5-Compatible Communication (SEND/RECEIVE Interface)
on FDL Connections B3-12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3 Data of FMS Connections B3-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.4 Characteristics of S7 Communication B3-14. . . . . . . . . . . . . . . . . . . . . . . . . . .
5.5 Maximum Number of Connections in Total B3-16. . . . . . . . . . . . . . . . . . . . . . .
5.6 Time-of-day Synchronization B3-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.7 Use in Fault-Tolerant Systems B3-17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.8 Other Characteristics B3-18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Compatibility with the Previous Product B3-19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1 Extended Functionality Compared with Previous Product B3-19. . . . . . . . . .
6.2 Replacing Older Modules / Replacing Defective Modules B3-20. . . . . . . . . .
7 Technical Specifications B3-22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Properties / Services
B3-4
CP 443-5 Basic for PROFIBUS / Manual Part B3
Release 11/2002
C79000-G8976-C161-04
Properties / Services
Application
The CP 443-5 Basic communications processor is designed for use in a SIMATIC
S7-400 (standard) and S7-400H (fault-tolerant system) programmable controller. It
allows the S7-400 / S7-400H to be connected to a PROFIBUS fieldbus system.
Services
The current version of the CP 443-5 Basic supports the following communication
services in the standard and H systems:
S PROFIBUS FMS (complying with EN 50170, FMS client and server function)
as FMS master for the following types of connection:
- MMAC: Master-master acyclic
- MSAC: Master-slave acyclic
- MSAC_SI: Master-slave acyclic with slave initiative
- MSCY: Master slave cyclic
- BRCT (broadcast): Sending to all FMS stations
S S7 communication and PG/OP communication
- PG functions with upload / download of FM modules, configuration /
diagnostics and routing, user programs
Note on routing: Dynamic switchover to alternative paths (for example if
there is a problem on one of the possible transmission paths) is not
supported.
- Operator control and monitoring functions (HMI)
- Data exchange using communication function blocks on S7 connections
(fault-tolerant S7 connections also possible)
1
)
1)
Blocks for S7 communication (see also STEP 7 online help or
“System Software for S7-300/400 System and Standard Functions” manual):
BSEND SFB 12
BRCV SFB 13
PUT SFB 14
GET SFB 15
USEND SFB 8
URCV SFB 9
START SFB 19
STOP SFB 20
RESUME SFB 21
STATUS SFB 22
USTATUS SFB 23
CONTROL SFC 62
1
Properties / Services
B3-5
CP 443-5 Basic for PROFIBUS / Manual Part B3
Release 11/2002
C79000-G8976-C161-04
S S5-compatible communication (SEND/RECEIVE Interface) over FDL
connections of the following types:
- specified FDL connections
- free layer 2 connections
- broadcast
- multicast
S Time-of-day synchronization over PROFIBUS
- The CP forwards time-of-day synchronization frames from the LAN to the
station (CPU = time slave) or from the station to the LAN (CPU= time
master) or this station is synchronized via a different LAN and the
time-of-day synchronization frame must be forwarded over PROFIBUS for
the synchronization of further stations.
- Time-of-day status value, standard/daylight saving time switchover,
synchronization status
The services of the CP 443-5 Basic module listed above can be used at the same
time.
Configuration
When configuring, you must use STEP 7 version V5.2 SP1 or higher; for FDL
connections and diagnostic functions, the NCM S7 for PROFIBUS optional
package supplied with STEP 7 must be installed.
If the functionality of the predecessor module is adequate for your purposes,
configuration and diagnostics are also possible with earlier STEP 7 versions.
It is possible to configure over the MPI or LAN/PROFIBUS.
System modifications are possible during operation (H system).
Note
For more detailed information on configuring PROFIBUS CP with STEP 7 /
NCM S7, refer to the manual NCM S7 for PROFIBUS and the online help of
STEP 7.
Programming - Using Blocks
For some communication services, there are “off-the-peg” blocks (FCs/FBs)
available that implement the interface in your STEP 7 user program. You will find a
detailed description of these blocks in the NCM S7 for PROFIBUS manuals.
剩余21页未读,继续阅读
lieewei
- 粉丝: 0
- 资源: 4
上传资源 快速赚钱
- 我的内容管理 收起
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
会员权益专享
最新资源
- ExcelVBA中的Range和Cells用法说明.pdf
- 基于单片机的电梯控制模型设计.doc
- 主成分分析和因子分析.pptx
- 共享笔记服务系统论文.doc
- 基于数据治理体系的数据中台实践分享.pptx
- 变压器的铭牌和额定值.pptx
- 计算机网络课程设计报告--用winsock设计Ping应用程序.doc
- 高电压技术课件:第03章 液体和固体介质的电气特性.pdf
- Oracle商务智能精华介绍.pptx
- 基于单片机的输液滴速控制系统设计文档.doc
- dw考试题 5套.pdf
- 学生档案管理系统详细设计说明书.doc
- 操作系统PPT课件.pptx
- 智慧路边停车管理系统方案.pptx
- 【企业内控系列】企业内部控制之人力资源管理控制(17页).doc
- 温度传感器分类与特点.pptx
资源上传下载、课程学习等过程中有任何疑问或建议,欢迎提出宝贵意见哦~我们会及时处理!
点击此处反馈
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功
评论0