没有合适的资源?快使用搜索试试~ 我知道了~
首页三菱plc 通信 MX Component 手册
三菱plc 通信 MX Component 手册
5星 · 超过95%的资源 需积分: 50 67 下载量 120 浏览量
更新于2023-03-16
评论 1
收藏 5.09MB PDF 举报
三菱plc 通信 MX Component 手册,MX Component 是一个工具,通过使用该工具,可以在无需具备通信协议及模块知识的状况下实现从个人计算机至可编 程控制器的通信。 通过使用通用的函数,可以使迄今为止麻烦且复杂的串行通信及以太网通信的程序开发变得异常简单。 将本手册中介绍的程序示例应用于实际系统时,应充分验证对象系统中不存在控制方面的问题
资源详情
资源评论
资源推荐
1
SAFETY PRECAUTIONS
(Read these precautions before using this product.)
Before using this product, please read this manual and the relevant manuals carefully and pay full attention
to safety to handle the product correctly.
In this manual, the safety precautions are classified into two levels: " WARNING" and " CAUTION".
Under some circumstances, failure to observe the precautions given under " CAUTION" may lead to
serious consequences.
Make sure that the end users read this manual and then keep the manual in a safe place for future
reference.
[Design Instructions]
WARNING
● When data change, program change, or status control is performed from a personal computer to a
running programmable controller, create an interlock circuit outside the programmable controller to
ensure that the whole system always operates safely.
Furthermore, for the online operations performed from a personal computer to a programmable
controller CPU, the corrective actions against a communication error due to such as a cable
connection fault should be predetermined as a system.
CAUTION
● The online operations performed from a personal computer to a running programmable controller
CPU (forced output and operating status changes) must be executed after the manual has been
carefully read and the safety has been ensured.
The operation failure may cause the injury or machine damage.
WARNING
CAUTION
Indicates that incorrect handling may cause hazardous conditions,
resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions,
resulting in minor or moderate injury or property damage.
2
CONDITIONS OF USE FOR THE PRODUCT
(1) Mitsubishi programmable controller ("the PRODUCT") shall be used in conditions;
i) where any problem, fault or failure occurring in the PRODUCT, if any, shall not lead to any major
or serious accident; and
ii) where the backup and fail-safe function are systematically or automatically provided outside of
the PRODUCT for the case of any problem, fault or failure occurring in the PRODUCT.
(2) The PRODUCT has been designed and manufactured for the purpose of being used in general
industries.
MITSUBISHI SHALL HAVE NO RESPONSIBILITY OR LIABILITY (INCLUDING, BUT NOT
LIMITED TO ANY AND ALL RESPONSIBILITY OR LIABILITY BASED ON CONTRACT,
WARRANTY, TORT, PRODUCT LIABILITY) FOR ANY INJURY OR DEATH TO PERSONS OR
LOSS OR DAMAGE TO PROPERTY CAUSED BY the PRODUCT THAT ARE OPERATED OR
USED IN APPLICATION NOT INTENDED OR EXCLUDED BY INSTRUCTIONS, PRECAUTIONS,
OR WARNING CONTAINED IN MITSUBISHI'S USER, INSTRUCTION AND/OR SAFETY
MANUALS, TECHNICAL BULLETINS AND GUIDELINES FOR the PRODUCT.
("Prohibited Application")
Prohibited Applications include, but not limited to, the use of the PRODUCT in;
• Nuclear Power Plants and any other power plants operated by Power companies, and/or any
other cases in which the public could be affected if any problem or fault occurs in the PRODUCT.
• Railway companies or Public service purposes, and/or any other cases in which establishment of
a special quality assurance system is required by the Purchaser or End User.
• Aircraft or Aerospace, Medical applications, Train equipment, transport equipment such as
Elevator and Escalator, Incineration and Fuel devices, Vehicles, Manned transportation,
Equipment for Recreation and Amusement, and Safety devices, handling of Nuclear or
Hazardous Materials or Chemicals, Mining and Drilling, and/or other applications where there is a
significant risk of injury to the public or property.
Notwithstanding the above, restrictions Mitsubishi may in its sole discretion, authorize use of the
PRODUCT in one or more of the Prohibited Applications, provided that the usage of the PRODUCT
is limited only for the specific applications agreed to by Mitsubishi and provided further that no
special quality assurance or fail-safe, redundant or other safety features which exceed the general
specifications of the PRODUCTs are required. For details, please contact the Mitsubishi
representative in your region.
3
OPERATING CONSIDERATIONS
This section explains the considerations in the following order.
1) Considerations of operating system and personal computer to be used
2) Considerations of installation and uninstallation
3) Programmable controller CPU-related considerations
4) Considerations for using other MELSOFT products
5) Considerations for using Ethernet modules
6) Considerations for using CC-Link modules
7) Considerations for using serial communication modules
8) Considerations of modem communication
9) Considerations of programming
10) Considerations for using Microsoft
®
Excel
®
11) Considerations for using Microsoft
®
Access
®
12) Considerations for using VBScript
13) Considerations for using of Robot controller
(1) Restrictions applied when a user without Administrator’s authority operates MX Component
Note that the following restrictions are applied when a user without Administrator’s authority operates MX
Component.
(a) Communication Setup Utility
• The logical station number cannot be created, changed, or deleted.
• Communication settings cannot be imported.
• This utility cannot be started up if the communication settings are set using MX Component earlier than
Version 3.00A.
*1
(b) PLC Monitor Utility
• This utility cannot be started up if the communication settings are set using MX Component earlier than
Version 3.00A.
*1
• Device registration cannot be performed on the <<Entry Device>> tab.
(c) Communication board
• Various settings cannot be set on the CC-Link IE Controller Network, CC-Link IE Field Network,
MELSECNET/H, and CC-Link board utilities.
*1 : If the following error message is displayed, start up and close the utility as a user with Administrator’s authority. This
operation enables a user without Administrator’s authority to start up the utility.
(2) Resume and other functions of personal computer
A communication error may occur when communicating with the programmable controller CPU after setting the
resume function, suspend setting, power-saving function, and/or standby mode of the personal computer.
Therefore, do not set the above functions when communicating with the programmable controller CPU.
Considerations of operating system and personal computer to be used
剩余573页未读,继续阅读
u013518770
- 粉丝: 34
- 资源: 22
上传资源 快速赚钱
- 我的内容管理 收起
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
会员权益专享
最新资源
- c++校园超市商品信息管理系统课程设计说明书(含源代码) (2).pdf
- 建筑供配电系统相关课件.pptx
- 企业管理规章制度及管理模式.doc
- vb打开摄像头.doc
- 云计算-可信计算中认证协议改进方案.pdf
- [详细完整版]单片机编程4.ppt
- c语言常用算法.pdf
- c++经典程序代码大全.pdf
- 单片机数字时钟资料.doc
- 11项目管理前沿1.0.pptx
- 基于ssm的“魅力”繁峙宣传网站的设计与实现论文.doc
- 智慧交通综合解决方案.pptx
- 建筑防潮设计-PowerPointPresentati.pptx
- SPC统计过程控制程序.pptx
- SPC统计方法基础知识.pptx
- MW全能培训汽轮机调节保安系统PPT教学课件.pptx
资源上传下载、课程学习等过程中有任何疑问或建议,欢迎提出宝贵意见哦~我们会及时处理!
点击此处反馈
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功
评论1