三菱opc的运用 The MELSEC OPC Server is an application designed to operate with Microsoft Windows 2000/NT/98/95 as an OPC local/ remote server for OPC Data Access2.0. And it is designed for use with the MELSEC- OPC Server provides MELSEC communication service to OPC Client software (for example Wonderware InTouch,Intellution iFix,Rockwell RS-View etc). Also it supports OPC Automation interface to use from Microsoft Visual Basic and Excel(VBA).
资源详情
资源评论
资源推荐

-1-
MELSEC OPC
Server
Data sheet
About MELSEC OPC Server
The MELSEC OPC Server is an application
designed to operate with Microsoft Windows
2000/NT/98/95 as an OPC local/ remote
server for OPC Data Access2.0. And it is
designed for use with the MELSEC- A/Q series.
OPC Server provides MELSEC communication
service to OPC Client software (for example
Wonderware InTouch,Intellution iFix,Rockwell
RS- View etc). Also it supports OPC
Automation interface to use from Microsoft
Visual Basic and Excel(VBA).
MELSECNET
CCLink
Windows95/98/NT4.0
Ethernet
MELSECBoard
MELSEC-A/Q MELSEC-A/Q
MELSEC-A/Q MELSEC-A/Q
RS232C
OLEAutomation
Interface
MELSEC OPC Server
(MelsecExplorer)
OPCClient
VisualBASIC
EXCEL(VBA)
CustomI/F
OPCClient
DCOM
■Feature and Function
Ø MELSEC communication interface
Ethernet
Serial communication link
PC interface board
(MELSECNET/10/CC-Link etc)
Ø MELSEC-A/QnA/Q system supported
Ø Free threading server
Ø OPC Automation interface support
Ø Tag data import/export
Ø Automatic Tag registry
Ø Data Type
Boolean/WORD/Double WORD/REAL/STRING
Ø Scale convert
Ø Simulationmode
(RAMP/SIN/RANDOM/DUMMY)
Ø Tag monitor
Ø Communication log
System Requirement
PC system requirement
PC running Windows 2000/NT/98/95.
A 200 MHz Pentium CPU or better.
(Intel brand CPU is required)
64 MB RAM total
Required Hard Drive Space:10 MB or more
Operating system
Windows2000/NT4.0 or Windows95/98
(For Windows 98/95, DCOM for Windows 98/95 is needed)
PLC System
■CPU System
MELSEC-An/AnN/AnA/AnU/ AnS/AnSH/A0J2(H)
MELSEC-QnA/QnAS/Qn
■Serial communication unit
AJ71C24-S8 An/AnA/AnA series
AJ71UC24 AnU series
A1SJ71UC24-R2/R4 AnS/US series
AJ71QC24(N)-R2/R4 QnA series
A1SJ71QC24(N)-R2/R4 QnAS series
QJ71C24(-R2) Q series
■Ethernet Unit
AJ71E71-S3 A/An/AnA/AnU series
A1SJ71E71-B2/B5-S3 AnS/AnUS series
AJ71QE71 QnA series
A1SJ71QE71-B2/B5 QnAS series
QJ71E71(-B2) Q series
■PC interface board
A70BD-J71AP23 MELSECNET2 optical
A70BD-J71QLP23 MELSECNET10optical
A70BD-J71QBR13 MELSECNET10coax bus
Q80BD-J71LP21-25 MELSECNET/H optical
Q80BD-J71BR11 MELSECNET/H coax bus
A70BD-AF A bus interface board
A80BD-A2USH-S1 A2USH CPU board
A80BD-J61BT11
A80BD-J61BT13
CC-Link Master board
CC-Link Local board
■CSKP
CPU port CPU communication port
LLT Ladder logic test
[Note] MELSEC software, SWnD5F-CSKP, is needed
when you use CSKP.