OV13850_R2A Calibration and OTP Programming Guide
OV13850_R2A Calibration and OTP Programming
Guide
Last Modified: Jun 27
th
, 2014
Document Revision: 3.03C
This document is provided "as is" with no warranties whatsoever, including any warranty of merchantability, non-infringement, fitness for any particular
purpose, or any warranty otherwise arising out of any proposal, specification, or sample. OmniVision Technologies,Inc. and all its affiliates disclaim all liability, including
liability for infringement of any proprietary rights, relating to the use of information in this document. No license, expressed or implied, by estoppel or otherwise, to any
intellectual property rights is granted herein. The information contained in this document is considered proprietary to OmniVision Technologies, Inc. and all its affiliates.
This information may be distributed to individuals or organizations authorized by OmniVision Technologies,Inc. to receive said information. Individuals and/or
organizations are not allowed to re-distribute said information.
OV13850_R2A Calibration and OTP Programming Guide
Content
1.1 Lens Correction Calibration........................................................................................................4
1.1.1 Module to module Variation of Lens shading and Color shading......................................4
1.1.2 Shading Variation Under Different Color Temperature......................................................6
1.1.3 Lens Correction Calibration Method..................................................................................6
1.1.4 Lens Correction Calibration Operation Procedure.............................................................7
1.2 White Balance Calibration.......................................................................................................11
1.2.1 Variation of Sensor/Lens/IR Color Response...................................................................11
1.2.2 Method of White Balance Calibration.............................................................................11
1.2.3 Operation Procedure of White Balance Calibration........................................................12
1.3 VCM Calibration.......................................................................................................................13
1.3.1 Variation of VCM .............................................................................................................13
1.3.2 VCM Calibration Method.................................................................................................14
2.1 OV13850_R2A OTP Structure..................................................................................................14
2.2 OV13850_R2A OTP Assignment for Calibration Data..............................................................15
2.3 MID and Lens ID number for OV13850_R2A...........................................................................23
2.4 Procedure of OV13850_R2A Read and Program OTP Content................................................25
2.4.1 Check OTP Group.............................................................................................................25
2.4.2 Program Calibration Data to OTP.....................................................................................26
2.4.3 Read Calibration Data from OTP......................................................................................26
3.1 Uniformity analysis tools – CameraAnalyzer.exe.....................................................................28
3.2 OTP Read/Program tools – OTP_Tool.exe................................................................................29
3.3 Lens correction calculation library for calibration-- LC.library.................................................30
3.4 OTP Apply Driver Sample Code(**).........................................................................................30
This document is provided "as is" with no warranties whatsoever, including any warranty of merchantability, non-infringement, fitness for any particular
purpose, or any warranty otherwise arising out of any proposal, specification, or sample. OmniVision Technologies,Inc. and all its affiliates disclaim all liability, including
liability for infringement of any proprietary rights, relating to the use of information in this document. No license, expressed or implied, by estoppel or otherwise, to any
intellectual property rights is granted herein. The information contained in this document is considered proprietary to OmniVision Technologies, Inc. and all its affiliates.
This information may be distributed to individuals or organizations authorized by OmniVision Technologies,Inc. to receive said information. Individuals and/or
organizations are not allowed to re-distribute said information.
OV13850_R2A Calibration and OTP Programming Guide
Revision History
Revision Changes Change by Approval by
'3.00C
1. Calibration Flow is changed.
WB calibration should be after LSC calibration.
2. ND filter is replaced with optical diffuser.
3. LSC setting change to 186 bytes after compress.
4. LSC ROI change from 5X5 to 12X10 for LSC color
shading. .
5. Add checksum byte in LSC part of OTP assignment.
6. Add 1X gain setting in 1.1.4.2.
7. Add production ID in 2.1.
8. Add LSC compress flag in 0x7248[1:0].
Celery Qi
'3.01C 1. Update drive code for for high efficiency. Celery Qi
'3.02C 1. Update the definition of checksum in LSC part. The
checksum is for the 360 bytes LSC data which are
decoded from the OTP LSC data.
2. Update drive code for checksum part.
Celery Qi
'3.03C 1.Update drive code for function.
2. Add 0x7220[1:0] for different OTP assignment.
Celery Qi
This document is provided "as is" with no warranties whatsoever, including any warranty of merchantability, non-infringement, fitness for any particular
purpose, or any warranty otherwise arising out of any proposal, specification, or sample. OmniVision Technologies,Inc. and all its affiliates disclaim all liability, including
liability for infringement of any proprietary rights, relating to the use of information in this document. No license, expressed or implied, by estoppel or otherwise, to any
intellectual property rights is granted herein. The information contained in this document is considered proprietary to OmniVision Technologies, Inc. and all its affiliates.
This information may be distributed to individuals or organizations authorized by OmniVision Technologies,Inc. to receive said information. Individuals and/or
organizations are not allowed to re-distribute said information.
OV13850_R2A Calibration and OTP Programming Guide
OV13850_R2A sensor has 8k bits embedded OTP(One Time Programmable) memory, which is
enough to store camera module calibration data. This document provides general guidelines for
OV13850_R2A camera module calibration, including calibration items and methodology and OTP
programming procedure.
1. OV13850_R2A Camera Module Calibration
OV13850_R2A Camera Module Calibration includes following calibration items: Lens Correction
,White Balance, VCM.
OTP calibration setting includes two parts -- sensor initial setting + OTP key setting. Please don't
load OV DB setting directly.
From ISP pipeline's view, LSC and AWB calibration flow have been changed to get high AWB
calibration accuracy. LSC calibration data should be written back to sensor before AWB
calibration. Please refer to figure 1 to get detail calibration flow.
Figure 1, Calibration flow
1.1 Lens Correction Calibration
1.1.1 Module to module Variation of Lens shading and Color shading
The lens shading also has module to module variation. The variation comes from the following
reasons:
1. Camera module assembly variation such as lens holder alignment with camera module
2. Lens assembly variation
3. Sensor micro lens variation(sensor CRA variation).
4. Pan/tilt of image sensor during assembly
The lens shading variation includes luminance shading, which is very clear shown in Figure 2 and
color shading which is not easy to identify by naked eye without doing lens correction and white
balance. CameraAnalyzer which is introduced in Section 3.1 can be used for the lens shading
analysis.
This document is provided "as is" with no warranties whatsoever, including any warranty of merchantability, non-infringement, fitness for any particular
purpose, or any warranty otherwise arising out of any proposal, specification, or sample. OmniVision Technologies,Inc. and all its affiliates disclaim all liability, including
liability for infringement of any proprietary rights, relating to the use of information in this document. No license, expressed or implied, by estoppel or otherwise, to any
intellectual property rights is granted herein. The information contained in this document is considered proprietary to OmniVision Technologies, Inc. and all its affiliates.
This information may be distributed to individuals or organizations authorized by OmniVision Technologies,Inc. to receive said information. Individuals and/or
organizations are not allowed to re-distribute said information.
Sensor initial setting
+ OTP Key setting
LSC calibration
AWB calibration
Capture Raw
image 1
Enable LSC and write
back LSC calibration
result to sensor
Capture Raw
image 2
OV13850_R2A Calibration and OTP Programming Guide
Figure 2, Lens Shading Variation --- original
Figure 3, Color Shading After Lens Correction and white balance
This document is provided "as is" with no warranties whatsoever, including any warranty of merchantability, non-infringement, fitness for any particular
purpose, or any warranty otherwise arising out of any proposal, specification, or sample. OmniVision Technologies,Inc. and all its affiliates disclaim all liability, including
liability for infringement of any proprietary rights, relating to the use of information in this document. No license, expressed or implied, by estoppel or otherwise, to any
intellectual property rights is granted herein. The information contained in this document is considered proprietary to OmniVision Technologies, Inc. and all its affiliates.
This information may be distributed to individuals or organizations authorized by OmniVision Technologies,Inc. to receive said information. Individuals and/or
organizations are not allowed to re-distribute said information.
剩余38页未读,继续阅读
心妤
- 粉丝: 14
- 资源: 20
上传资源 快速赚钱
- 我的内容管理 收起
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
会员权益专享
最新资源
- c++校园超市商品信息管理系统课程设计说明书(含源代码) (2).pdf
- 建筑供配电系统相关课件.pptx
- 企业管理规章制度及管理模式.doc
- vb打开摄像头.doc
- 云计算-可信计算中认证协议改进方案.pdf
- [详细完整版]单片机编程4.ppt
- c语言常用算法.pdf
- c++经典程序代码大全.pdf
- 单片机数字时钟资料.doc
- 11项目管理前沿1.0.pptx
- 基于ssm的“魅力”繁峙宣传网站的设计与实现论文.doc
- 智慧交通综合解决方案.pptx
- 建筑防潮设计-PowerPointPresentati.pptx
- SPC统计过程控制程序.pptx
- SPC统计方法基础知识.pptx
- MW全能培训汽轮机调节保安系统PPT教学课件.pptx
资源上传下载、课程学习等过程中有任何疑问或建议,欢迎提出宝贵意见哦~我们会及时处理!
点击此处反馈
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功
评论0