DOP
-B07
High Color‧Wide Screen‧
User-Friendly HMI Products
B07S411/B07S411K Instrunction Sheet
(1) Preface
Thank you for purchasing DELTA’s DOP-B series. This instruction sheet will be helpful in the installation,
wiring and inspection of Delta HMI. Before using the product, please read this instruction sheet to ensure
correct use. You should thoroughly understand all safety precautions before proceeding with the
installation, wiring and operation. Place this instruction sheet in a safe location for future reference. Please
observe the following precautions:
Install the product in a clean and dry location free from corrosive and inflammable gases or liquids.
Ensure that all wiring instructions and recommendations are followed.
Ensure that HMI is correctly connected to a ground. The grounding method must comply with the
electrical standard of the country (Please refer to NFPA 70: National Electrical Code, 2005 Ed.).
Do not disassemble HMI, modify or remove wiring when power is applied to HMI.
Do not touch the power supply during operation. Otherwise, it may cause electric shock.
If you have any questions during operation, please contact our local distributors or Delta sales
representatives.
The content of this instruction sheet may be revised without prior notice. Please consult our distributors or
download the most updated version at http://www.delta.com.tw/industrialautomation
.
(2) Pin Definition of Serial Communication
DOP-B07S411 / DOP-B07S411K COM1 Port
MODE1
COM Port PIN
RS-232
1
2 RXD
3 TXD
4
5 GND
6
7 RTS
8 CTS
9
DOP-B07S411 / DOP-B07S411K COM2 Port
MODE1 MODE2 MODE3
COM2 COM3 COM2 COM3 COM2 COM3
COM Port PIN
RS-232 RS-485 RS-485 RS-485 RS-232 RS-422
1 D+ TXD+
2 RXD RXD
3 TXD TXD
4 D+ D+ RXD+
5 GND GND GND
6 D- TXD-
7
8
9 D- D- RXD-
Note1: Blank = No Connection.
(3) Parts Names
DOP-B07S411 (Front View)
A Touch Screen / Display B Power LED Indicator
DOP-B07S411K (Front View)
A
User-defined Function Keys / System Keys
User-defined Function Keys: F1, F2, F3, F4
System Keys: , , , SYS
B
: Power LED Indicator
Lights in green when HMI works normally.
C
: Operation LED Indicator (Blue)
(Note1)
The operation LED indicator blinks in blue when either the communication is carried
out or the data is accessing (please refer to the “Note1” below for explanation).
: Alarm LED Indicator (Red)
The alarm LED indicator blinks in red when one of the alarms is on.
D Touch Screen / Display
NOTE
1. The definition of the operation LED indicator (Blue) can be determined by the users freely.
DOP-B07S411 / DOP-B07S411K (Rear View)
A Power Input Terminal B COM1
C COM2 D USB Slave
E USB Host F Battery Case / System Key
DOP-B07S411 / DOP-B07S411K
215
(8.46")
161
(6.34")
+1.0
196.9
0
+1.0
142.9
0
142.3
(5.6")
T
51.2(2.02")
Note:
T=1.6mm(0.063")~6mm(0.24")
+0.04"
(7.75" )
-0
+0.04"
(5.63" )
-0
D
A
(5) Specifications
C
B
MODEL
DOP-B07S411 DOP-B07S411K
Display Type
7" TFT LCD (65535 colors)
Resolution
800 x 480 pixels
Backlight
LED Back Light (less than 20,000 hours half-life at 25
o
C)
(Note 1)
LCD MODULE
Display Size
154.08 x 85.92mm 154.1 x 87.6mm
Operation System
Delta Real Time OS
MCU
32-bit RISC Micro-controller
NOR Flash ROM
Flash ROM 128 MB
(OS System: 30MB / Backup: 16MB / User Application: 82MB)
SDRAM
64Mbytes
Backup Memory
32Kbytes
Buzzer
Multi-Tone Frequency(2K ~ 4K Hz)/85dB
USB
1 USB Slave Ver 2.0
1 USB Host Ver 1.1
COM1
RS-232(supports hardware flow control)
COM2
RS-232 / RS-485
Serial
COM Port
COM3
RS-422 / RS-485
Function Key
N/A
User defined key x 4 +
System key x 4
Perpetual Calendar (RTC)
Built-in
Cooling Method
Natural air circulation
Safety Approval
CE
Waterproof Degree
IP65
Operation Voltage
(Note2)
DC +24V(-10% ~ +15%)(please use isolated power supply)
Voltage Endurance
AC500V for 1 minute (between charging (DC24V terminal)
and FG terminals)
Power Consumption
(Note 2)
4.0W
Backup Battery
3V lithium battery CR2032 × 1
Backup Battery Life
It depends on the temperature used and the conditions of usage,
about 3 years or more at 25
o
C.
Operation Temperature
0
o
C ~ 50
o
C
Storage Temperature
-20
o
C ~ +60
o
C
Ambient Humidity
10% ~ 90% RH [0 ~ 40
o
C], 10% ~ 55% RH [41 ~ 50
o
C]
Pollution Degree 2
Vibration Resistance
IEC 61131-2 Compliant
5Hz≦f<9Hz = Continuous: 1.75mm / Occasional: 3.5mm
9Hz≦f≦150Hz = Continuous: 0.5g / Occasional: 1.0g
X, Y, Z directions for 10 times
Dimensions
(W) x (H) x (D) mm
215 x 161 x 50
Panel Cutout
(W) x (H) mm
196.9 x 142.9
Weight
Approx. 820g Approx. 840g
PIN1
(4) Dimensions
NOTE
1) The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving
current is supplied to HMI. The life of LED backlight shown here is an estimated value under 25
o
C normal
temperature and humidity conditions.
2) The value of the power consumption indicates the electrical power consumed by HMI only without connecting
to any peripheral devices. In order to ensure the normal operation, it is recommended to use a power supply
which the capacity is 1.5 ~2 times the value of the power consumption.
3) The content of this instruction sheet may be revised without prior notice. Please consult our distributors or
download the most updated version at http://www.delta.com.tw/industrialautomation/
.
A B
A
B
C
F
PIN1
E
D