SN74LVC4245A
OCTAL BUS TRANSCEIVER AND 3.3-V TO 5-V SHIFTER
WITH 3-STATE OUTPUTS
SCAS375G – MARCH 1994 – REVISED AUGUST 2003
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range for V
CCB
= 2.7 V to 3.6 V
(unless otherwise noted)
†
Supply voltage range, V
CCB
–0.5 V to 4.6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
: B port (see Note 3) –0.5 V to V
CCB
+ 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
O
: B port (see Note 3) –0.5 V to V
CCB
+ 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, I
IK
(V
I
< 0) –50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0) –50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
O
±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous current through V
CCB
or GND ±100 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
JA
(see Note 2): DB package 63°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DW package 46°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PW package 88°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 2. The package thermal impedance is calculated in accordance with JESD 51-7.
3. This value is limited to 4.6 V maximum.
recommended operating conditions for V
CCA
= 4.5 V to 5.5 V (see Note 4)
MIN MAX UNIT
V
CCA
Supply voltage 4.5 5.5 V
V
IH
High-level input voltage 2 V
V
IL
Low-level input voltage 0.8 V
V
I
Input voltage 0 V
CCA
V
V
O
Output voltage 0 V
CCA
V
I
OH
High-level output current –24 mA
I
OL
Low-level output current 24 mA
T
A
Operating free-air temperature –40 85 °C
NOTE 4: All unused inputs of the device must be held at the associated V
CC
or GND to ensure proper device operation. Refer to the TI application
report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
recommended operating conditions for V
CCB
= 2.7 V to 3.6 V (see Note 4)
MIN MAX UNIT
V
CCB
Supply voltage 2.7 3.6 V
V
IH
High-level input voltage V
CCB
= 2.7 V to 3.6 V 2 V
V
IL
Low-level input voltage V
CCB
= 2.7 V to 3.6 V 0.8 V
V
I
Input voltage 0 V
CCB
V
V
O
Output voltage 0 V
CCB
V
High-level output current
V
CCB
= 2.7 V –12
High-level output current
V
CCB
= 3 V –24
V
CCB
= 2.7 V 12
V
CCB
= 3 V 24
T
A
Operating free-air temperature –40 85 °C
NOTE 4: All unused inputs of the device must be held at the associated V
CC
or GND to ensure proper device operation. Refer to the TI application
report, Implications of Slow or Floating CMOS Inputs, literature number SCBA004.