BEGIN REGION Servo Power //Servo Power IF "AlwaysTRUE" AND "Control Voltage On" THEN "Robot1 Power for Servo 1-2" := "Robot2 Power for Servo 3-4" := "Robot3 Power for Servo 5-6" := "Robot4 Power for Travelling Servo 7-8" := "Robot5 Power for Travelling Servo 9-10" := true; ELSE "Robot1 Power for Servo 1-2" := "Robot2 Power for Servo 3-4" := "Robot3 Power for Servo 5-6" := "Robot4 Power for Travelling Servo 7-8" := "Robot5 Power for Travelling Servo 9-10" := FALSE; END_IF; //Servo Limit Sensor - 启用硬限位 IF "AlwaysTRUE" AND NOT "Buzzer Stop Button" THEN "DB1002_Control Status Epos".Robot1.X.CamAct := "DB1002_Control Status Epos".Robot1.Z.CamAct := "DB1002_Control Status Epos".Robot2.X.CamAct := "DB1002_Control Status Epos".Robot2.Z.CamAct := "DB1002_Control Status Epos".Robot3.X.CamAct := "DB1002_Control Status Epos".Robot3.Z.CamAct := "DB1002_Control Status Epos".Robot4.X.CamAct := "DB1002_Control Status Epos".Robot4.Z.CamAct := "DB1002_Control Status Epos".Robot5.X.CamAct := "DB1002_Control Status Epos".Robot5.Z.CamAct := "DB1002_Control Status Epos".Load.X.CamAct := "DB1002_Control Status Epos".UnLoad.X.CamAct := TRUE; ELSE "DB1002_Control Status Epos".Robot1.X.CamAct := "DB1002_Control Status Epos".Robot1.Z.CamAct := "DB1002_Control Status Epos".Robot2.X.CamAct := "DB1002_Control Status Epos".Robot2.Z.CamAct := "DB1002_Control Status Epos".Robot3.X.CamAct := "DB1002_Control Status Epos".Robot3.Z.CamAct := "DB1002_Control Status Epos".Robot4.X.CamAct := "DB1002_Control Status Epos".Robot4.Z.CamAct := "DB1002_Control Status Epos".Robot5.X.CamAct := "DB1002_Control Status Epos".Robot5.Z.CamAct := "DB1002_Control Status Epos".Load.X.CamAct := "DB1002_Control Status Epos".UnLoad.X.CamAct := false; END_IF; //Robot1 X Power And Reset "FC192_Robot_Power"("E-Stop" := "DB1002_Control Status Epos".Robot1.X."E-Stop", Fault := "DB1001_Actual Status Epos".Robot1.X.Fault, Ready := "DB1001_Actual Status Epos".Robot1.X.OFF1_Ready, "Alarm Reset" := "Alarm Reset", Off1 => "DB1002_Control Status Epos".Robot1.X.Off1, "Enable Temp" := "DB1003_Servo Button"."Robot1 X"."Servo enabled Temp", "Enable Reset" := "DB1003_Servo Button"."Robot1 X"."Servo enabled Reset", "Time" := "DB3_Time".Robot1.T65);
时间: 2024-01-12 14:03:53 浏览: 151
这段代码是一个程序的一部分,主要包含了一些条件判断和变量赋值。
首先,在 "Servo Power" 区域内,根据条件判断 "AlwaysTRUE" 和 "Control Voltage On" 的结果,设置了多个变量的值。如果条件为真,则将一些名为 "RobotX Power for Servo X-X" 的变量设置为 true;否则设置为 false。
接着,在 "Servo Limit Sensor - 启用硬限位" 区域内,根据条件判断 "AlwaysTRUE" 和 "Buzzer Stop Button" 的结果,设置了多个名为 "DB1002_Control Status Epos" 的变量的属性值。如果条件为真,则将这些变量的某个属性(CamAct)设置为 true;否则设置为 false。
最后,在 "Robot1 X Power And Reset" 部分,调用了一个名为 "FC192_Robot_Power" 的函数,并传递了多个参数。这些参数包括了一些变量和常量的值,用于控制机器人的电源和复位操作。
请注意,这只是代码的一部分,可能还有其他部分的代码没有提供。因此,完整理解代码功能需要考虑整个程序的逻辑。
阅读全文