RTS_INVALID_HANDLE
时间: 2023-09-08 18:16:40 浏览: 216
这是一个IT类问题。RTS_INVALID_HANDLE是Windows操作系统提供的一个错误码,表示句柄(handle)无效。在Windows编程中,句柄是对系统资源的引用,例如窗口、文件、进程等。当一个句柄被关闭或释放后,再次使用该句柄就会返回RTS_INVALID_HANDLE错误码。常见的解决方法是在使用句柄之前检查其是否依然有效。
相关问题
--------------------------------------------------------------------------- SerialException Traceback (most recent call last) C:\Users\ADMINI~1\AppData\Local\Temp/ipykernel_3612/870021424.py in <module> 3 4 # 串口初始化 ----> 5 ser = serial.Serial('COM6', 9600, timeout=1) # 修改为对应的串口号 6 7 # 向Arduino发送指令 D:\py\lib\site-packages\serial\serialwin32.py in __init__(self, *args, **kwargs) 31 self._overlapped_read = None 32 self._overlapped_write = None ---> 33 super(Serial, self).__init__(*args, **kwargs) 34 35 def open(self): D:\py\lib\site-packages\serial\serialutil.py in __init__(self, port, baudrate, bytesize, parity, stopbits, timeout, xonxoff, rtscts, write_timeout, dsrdtr, inter_byte_timeout, exclusive, **kwargs) 242 243 if port is not None: --> 244 self.open() 245 246 # - - - - - - - - - - - - - - - - - - - - - - - - D:\py\lib\site-packages\serial\serialwin32.py in open(self) 62 if self._port_handle == win32.INVALID_HANDLE_VALUE: 63 self._port_handle = None # 'cause __del__ is called anyway ---> 64 raise SerialException("could not open port {!r}: {!r}".format(self.portstr, ctypes.WinError())) 65 66 try: SerialException: could not open port 'COM6': PermissionError(13, '拒绝访问。', None, 5)
这个错误是由于权限问题导致的,你的程序无法访问COM6串口。请尝试以下解决方法:
1. 确保你的程序以管理员权限运行。右键点击你的代码编辑器(如PyCharm)的图标,选择“以管理员身份运行”。
2. 检查其他应用程序是否正在使用COM6串口,例如串口调试助手等。如果是,请关闭这些应用程序,然后重新运行你的程序。
3. 确保你的串口驱动程序已正确安装。可以尝试更新或重新安装驱动程序。
4. 如果你的计算机上有多个串口,尝试将代码中的串口号修改为其他可用的串口号,例如COM1或COM2。
如果以上方法仍无法解决问题,请提供更多关于你的操作系统、串口设备和驱动程序的信息,以便我能够提供更具体的帮助。
串口应用程序接收数据前通过RTS告知发送端接收缓冲区满了代码实现
下面是使用C语言实现串口应用程序通过RTS告知发送端接收缓冲区满了的代码示例:
```c
#include <windows.h>
#include <stdio.h>
#define BUFFER_SIZE 1024
int main()
{
HANDLE hComm;
BOOL fSuccess;
DWORD dwBytesRead, dwBytesWritten;
char szBuffer[BUFFER_SIZE];
COMMTIMEOUTS timeouts = { 0 };
DCB dcbSerialParams = { 0 };
BOOL bStatus;
// 打开串口
hComm = CreateFile("COM1", GENERIC_READ | GENERIC_WRITE, 0, NULL, OPEN_EXISTING, 0, NULL);
if (hComm == INVALID_HANDLE_VALUE)
{
printf("Error opening serial port\n");
return 1;
}
// 配置串口参数
dcbSerialParams.DCBlength = sizeof(dcbSerialParams);
bStatus = GetCommState(hComm, &dcbSerialParams);
dcbSerialParams.BaudRate = CBR_9600;
dcbSerialParams.ByteSize = 8;
dcbSerialParams.StopBits = ONESTOPBIT;
dcbSerialParams.Parity = NOPARITY;
bStatus = SetCommState(hComm, &dcbSerialParams);
// 设置超时参数
timeouts.ReadIntervalTimeout = 50;
timeouts.ReadTotalTimeoutConstant = 50;
timeouts.ReadTotalTimeoutMultiplier = 10;
timeouts.WriteTotalTimeoutConstant = 50;
timeouts.WriteTotalTimeoutMultiplier = 10;
bStatus = SetCommTimeouts(hComm, &timeouts);
// 读取数据并发送RTS信号
while (1)
{
fSuccess = ReadFile(hComm, szBuffer, BUFFER_SIZE, &dwBytesRead, NULL);
if (!fSuccess || dwBytesRead == 0)
{
printf("Error receiving data\n");
break;
}
if (dwBytesRead > BUFFER_SIZE / 2)
{
// 接收缓冲区已满,发送RTS信号
EscapeCommFunction(hComm, SETRTS);
}
fSuccess = WriteFile(hComm, szBuffer, dwBytesRead, &dwBytesWritten, NULL);
if (!fSuccess)
{
printf("Error sending data\n");
break;
}
if (dwBytesRead > BUFFER_SIZE / 2)
{
// 接收缓冲区已经处理完数据,发送RTS信号
EscapeCommFunction(hComm, CLRRTS);
}
}
CloseHandle(hComm);
return 0;
}
```
在上述代码中,当接收缓冲区的数据量超过缓冲区大小的一半时,就会发送RTS信号告知发送端停止发送数据。当接收缓冲区的数据量下降到缓冲区大小的一半以下时,就会发送RTS信号告知发送端可以继续发送数据。需要注意的是,这里的缓冲区大小是一个任意的值,实际应用中应该根据具体情况进行调整。
阅读全文