This Chapter specifies the KNX Datapoint Types for Interworking
This Chapter describes the general usable and Functional Block specific,
standard Datapoint Types that are to be used for transmission of data on
the bus.
Version 1.07.00 is a KNX Approved Standard.
System Specifications
Interworking
Datapoint Types
KNX Standard Interworking Datapoint Types
©Copyright 1998 - 2012, KNX Association System Specifications AS v1.07.00 - page 2 of 182
Document updates
Version Date Description
v1.0 AS
2002.01.03
Preparation of the approved standard.
The DPTs of the following documents are integrated.
− Chapter 7/1/3 (S12) “Logical Functional Blocks”
− Chapter 7/20 (S12) “Lighting”
− Chapter 7/50 (S12) “Shutters and Blinds”
− Supplement 11 “HVAC Datapoint Types”
− Supplement 12 “Channel Codes”
− Supplement 14 “DPT_DateTime”
− AN004 “Additional HVAC data types”
− AN006 “Update of Supplement 14 DPT_DateTime”
− AN027 “TFI approved Datapoint Types for general usage”
− AN035 “DPT_Version”
− AN079 “TFI Accepted DPTs 05.03”
Preparation of the Draft Proposal.
Editorial correction of DPT_TempFlowWaterDemAbs (DPT_ID = 210.100):
V
15
V
16
and B
8
B
16
in detailed specification, acc. resolution of
comments to AN096 v01.
Inclusion of resolution of comments from Final Voting.
Preparation of the Approved Standard.
v1.3 AS
2007.03.14
− DPT_Length_mm (7.011) added.
− DPT_Rotation_Angle (8.011) added.
− DPT_MBus_Address (230.1000)
PDT corrected from
PDT_GENERIC_09 to PDT_GENERIC_08.
v1.4 AS
2007.03.20
− AN050 “AN to Supplement 12” integrated.
2007.10.03
− AN051 “New channels” integrated.
2007.10.05
− AN087 “New channels 2005.02” integrated.
2007.10.19
Integrated conclusion of WGI meeting of 2007.09.26 about use of
DPT_Power and DPT_Value_Power.
2007.12.14
− AN057 “System B” integrated (DPT_ErrorClass_System extension)
2008.03.13
− AN096 “WGI accepted DPTs 06.01” started and completed integration.
−
AN098 “Unicode” started and completed integration.
2008.03.14
− AN066 “cEMI adaptations”: extension of DPT_CommMode.
2008.04.28
− PART_Logical, PART_Invert and PART_Input_Connected added
(AN050)
2008.05.19
− AN097 “Eberle Status Byte”: integration started and completed.
2008.06.04
− Coding of DPT_CommMode replaced by reference to
PID_COMM_MODE in 3/6/3.
2008.11.05
− AN105 to AN110: removed TP0 and PL132 from possible values of
DPT_Media
2009.02.03
− Editorial update for inclusion in the KNX Specifications v2.0.
2009.04.10
− 7/1/5 “General Purpose I/O”: added DPTs used in that specification.
v1.4 AS
2009.06.25
− Editorial update in view of inclusion in the KNX Specifications v2.0.
v1.4.01 AS
2009.11.10
− Correction of range of DPT_ErrorClass_System.
v1.5.00 AS
2009.11.18
− AN120 “WGI approved DPTs 07.01” integrated.
2010.04.14
− AN128 “WGI approved DPTs 09.01” integrated.
v1.5.01 AS
2010.11.26
− DPT_Trigger: added indication that both values 0 and 1 shall have the
same effect.
2011.01.04
− Added “KNX IP” to the enumeration of DPT_Media.
v1.5.02 AS
2011.02.12
− [WGI00052]: Indicated that DPT_HVACModeNext is generally usable,
not only on LTE, but also in Standard Mode and not only for HVAC.
− Numerous instances of “Z
8
” with font Arial 10 are replaced by
appropriate formatting without specific font.
KNX Standard Interworking Datapoint Types
©Copyright 1998 - 2012, KNX Association System Specifications AS v1.07.00 - page 3 of 182
Version Date Description
v1.5.03 AS
2011.05.06
− AN131 “DPT Prioritised Mode Control” integrated.
− DPT_RegionCodeAlpha2_ASCII and DPT_Locale_ASCII: ZZ can be
used for “no region”.
− Usage of DPT_ScalingSpeed more free.
v1.6.01 AS
2011.09.14
− [WGI00072] Update with the DPTs of the FB ADA:
DPT_FlowRate_m3/h, DPT_StatusAct, DPT_FlowRate_m3/h_Z,
DPT_Percent_V16_Z, DPT_DamperMode, DPT_ADAType,
DPT_BackupMode and DPT_StartSynchronization.
v1.07.00 AS
2012.03.13
− DPTs of Chapter 7/20/3 “DALI Proxy Basic” integrated.
2012.03.19
− AN141 “Lighting Sensors – LTE extensions” integrated.
− AN142 “Lighting actuators – LTE extensions” integrated.
− AN143 “Shutters and blinds Sensors – LTE extensions” integrated.
− AN144 “Shutters and blinds actuators – LTE extensions” integrated.
− DPT_BlinkingMode (20.603) of Chapter 7/1/5 integrated.
2012.04.26
− AN130 “Realisation of Submetering application with tariff”
integrated. Coding of validity bits in DPT_Tariff_ActiveEnergy adjusted
according WGI agreement.
References
[01]
Chapter 3/6/3
“External Message Interface”
[02]
Chapter 3/7/3
“Standard Identifier Tables”
[03]
Volume 7
“Application Descriptions”
Filename:
03_07_02 Datapoint Types v1.07.00 AS.docx
Version:
1.07.00
Status:
Approved Standard
Savedate:
2012.04.26
Number of pages:
182
KNX Standard Interworking Datapoint Types
©Copyright 1998 - 2012, KNX Association System Specifications AS v1.07.00 - page 4 of 182
Contents
1 Introduction ............................................................................................................................ 9
1.1 Classification and identification of Datapoint Types ..................................................... 9
1.2 Subtype ranges for Datapoint Type Identifiers ............................................................. 10
1.3 Datapoint Type specification style ............................................................................... 11
1.3.1 Notations and format......................................................................................... 11
1.3.2 Property Datatype ............................................................................................. 11
1.3.3 Use .................................................................................................................... 12
1.4 The transmission of DPT encoded data on the bus ....................................................... 12
2 Overview ............................................................................................................................... 13
3 Datapoint Types for common use ....................................................................................... 20
3.1 Datapoint Types B
1
....................................................................................................... 20
3.2 Datapoint Types B
2
....................................................................................................... 22
3.3 Datapoint Types B
1
U
3
................................................................................................... 23
3.3.1 DPT_Control_Dimming ................................................................................... 23
3.3.2 DPT_Control_Blinds ........................................................................................ 24
3.4 Datapoint Types Character Set” ................................................................................... 25
3.5 Datapoint Types “8-Bit Unsigned Value” .................................................................... 26
3.5.1 Scaled values ..................................................................................................... 26
3.5.2 Non-scaled values ............................................................................................. 27
3.6 Datapoint Types V
8
....................................................................................................... 28
3.6.1 Signed Relative Value....................................................................................... 28
3.7 Datapoint Type “Status with Mode” ............................................................................. 28
3.8 Datapoint Types “2-Octet Unsigned Value” ................................................................ 29
3.8.1 2-octet unsigned counter value ......................................................................... 29
3.8.2 Time Period ....................................................................................................... 29
3.8.3 Other U
16
Datapoint Types ............................................................................... 30
3.9 Datapoint Types “2-Octet Signed Value” ..................................................................... 31
3.9.1 2-octet signed counter value ............................................................................. 31
3.9.2 Delta Time ........................................................................................................ 31
3.9.3 Other V
16
Datapoint Types ............................................................................... 32
3.10 Datapoint Types “2-Octet Float Value” ....................................................................... 32
3.11 Datapoint Type “Time” ................................................................................................ 34
3.12 Datapoint Type “Date” ................................................................................................. 34
3.13 Datapoint Types “4-Octet Unsigned Value” ................................................................ 35
3.14 Datapoint Types “4-Octet Signed Value” ..................................................................... 35
3.14.1 4 Octet signed counter value ............................................................................. 35
3.14.2 DPTs for electrical energy ................................................................................ 36
3.14.3 4 Octet signed time period ................................................................................ 36
3.15 Datapoint Types “4-Octet Float Value” ....................................................................... 37
3.16 Datapoint Type DPT_Access_Data .............................................................................. 39
3.17 Datapoint Types "String" .............................................................................................. 41
3.18 Datapoint Type Scene Number ..................................................................................... 41
3.19 Datapoint Type DPT_SceneControl ............................................................................. 42
3.20 Datapoint Type DPT_DateTime ................................................................................... 43
3.20.1 Notes ................................................................................................................. 44
3.21 Datapoint Types N
8
....................................................................................................... 46
3.22 Datapoint Type B
8
........................................................................................................ 50
3.22.1 Datapoint Type “General Status”...................................................................... 50
3.22.2 Datapoint Type “Device Control” .................................................................... 51
KNX Standard Interworking Datapoint Types
©Copyright 1998 - 2012, KNX Association System Specifications AS v1.07.00 - page 5 of 182
3.23 Datapoint Types N
2
....................................................................................................... 52
3.24 Datapoint Type DPT_VarString_8859_1 ..................................................................... 53
3.25 Datapoint Type DPT_SceneInfo ................................................................................... 54
3.26 Datatype B
32
.................................................................................................................. 55
3.26.1 Datapoint Type “Combined Info On Off” ........................................................ 55
3.27 Datapoint Type Unicode UTF-8 String A[n] ................................................................ 58
3.27.1 DPT_UTF-8 ...................................................................................................... 58
3.28 Datapoint Types V
64
..................................................................................................... 60
3.28.1 DPTs for electrical energy ................................................................................ 60
3.29 Datapoint Type DPT_AlarmInfo .................................................................................. 61
3.30 Datapoint Type DPT_SerNum ..................................................................................... 64
3.31 Datapoint Types “Unsigned Relative Value” ............................................................... 64
3.32 Datapoint Types “Unsigned Counter Value” ............................................................... 65
3.33 Datapoint Types “Time Period..._Z” ............................................................................ 66
3.34 Datapoint Types “Unsigned Flow Rate l/h” ................................................................. 67
3.35 Datapoint Types “Unsigned Counter Value” ............................................................... 67
3.36 Datapoint Types “Unsigned Electric Current μA” ....................................................... 68
3.37 Datapoint Types “Power in kW” .................................................................................. 68
3.38 Datapoint Type “Atmospheric Pressure with Status/Command” ................................. 69
3.38.1 Datapoint Type “DPT_PercentU16_Z” ............................................................ 70
3.39 Datapoint Types “Signed Relative Value” ................................................................... 70
3.40 Datapoint Type “DeltaTime...Z” .................................................................................. 71
3.41 Datapoint Type “16 bit Signed Relative Value_Z” ...................................................... 72
3.42 Datapoint Type DPT_Version ...................................................................................... 73
3.43 Datatype V
32
Z
8
.............................................................................................................. 74
3.43.1 Datapoint Type “Volume in Liter” ................................................................... 74
3.43.2 Datapoint Type “Flow Rate in m3/h_Z” ........................................................... 75
3.44 Datatype U
16
U
8
............................................................................................................. 75
3.44.1 Datapoint Type “Scaling speed” ....................................................................... 75
3.44.2 Datapoint Type “Scaling step time” ................................................................. 77
3.44.3 DPT_TariffNext ................................................................................................ 78
3.45 Datatype V
32
N
8
Z
8
......................................................................................................... 78
3.45.1 Datapoint Type “MeteringValue” ..................................................................... 78
3.46 Datatypes A
8
A
8
A
8
A
8
.................................................................................................... 80
3.47 Datapoint Types A
8
A
8
.................................................................................................. 81
3.47.2 Datapoint Type DPT_RegionCodeAlpha2_ASCII ........................................... 83
3.48 DPT_Tariff_ActiveEnergy ........................................................................................... 87
3.49 DPT_Prioritised_Mode_Control ................................................................................... 88
3.49.1 Terms and abbreviations ................................................................................... 88
3.49.2 Definition .......................................................................................................... 88
3.49.3 Functional description ....................................................................................... 88
3.49.4 Use cases ........................................................................................................... 91
3.50 Datapoint Types B
2
U
6
................................................................................................... 92
3.50.1 DPT_SceneConfig ............................................................................................ 92
3.51 Datapoint Types U
8
r
7
B
1
................................................................................................ 93
3.51.1 DPT_FlaggedScaling ........................................................................................ 93
4 Datapoint Types for HVAC ................................................................................................. 94
4.1 Simple Datapoint Types with STATUS/COMMAND Z
8
field .................................... 94
4.1.1 Introduction ....................................................................................................... 94
4.1.2 Datatype format ................................................................................................ 95
4.1.3 OutOfService mechanism for a parameter ........................................................ 99
剩余181页未读,继续阅读
艾福安
- 粉丝: 0
- 资源: 1
上传资源 快速赚钱
- 我的内容管理 收起
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
会员权益专享
最新资源
- RTL8188FU-Linux-v5.7.4.2-36687.20200602.tar(20765).gz
- c++校园超市商品信息管理系统课程设计说明书(含源代码) (2).pdf
- 建筑供配电系统相关课件.pptx
- 企业管理规章制度及管理模式.doc
- vb打开摄像头.doc
- 云计算-可信计算中认证协议改进方案.pdf
- [详细完整版]单片机编程4.ppt
- c语言常用算法.pdf
- c++经典程序代码大全.pdf
- 单片机数字时钟资料.doc
- 11项目管理前沿1.0.pptx
- 基于ssm的“魅力”繁峙宣传网站的设计与实现论文.doc
- 智慧交通综合解决方案.pptx
- 建筑防潮设计-PowerPointPresentati.pptx
- SPC统计过程控制程序.pptx
- SPC统计方法基础知识.pptx
资源上传下载、课程学习等过程中有任何疑问或建议,欢迎提出宝贵意见哦~我们会及时处理!
点击此处反馈
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功
评论0