multiple (or no) load addresses: This is incompatible with uImages Specify LOADADDR on the commandline to build an uImage make[1]: *** [arch/arm/boot/uImage] Error 1 make: *** [uImage] Error 2
时间: 2023-09-05 22:09:01 浏览: 229
这个错误信息是由于在构建uImage镜像文件时,出现了多个或者没有指定LOADADDR(加载地址)的情况,而这种情况是与uImage不兼容的。解决这个问题,需要在命令行中指定LOADADDR,例如:
```
make uImage LOADADDR=0x80008000
```
其中,LOADADDR的值需要根据你的具体情况来设置。
相关问题
同样的代码为什么一个报错Traceback (most recent call last): File "C:\Users\a212\PycharmProjects\pythonProject4\f-s.py", line 700, in <module> socketio.run(app, host='0.0.0.0', port=7000, debug=False)#, allow_unsafe_werkzeug=True) File "C:\Users\a212\PycharmProjects\pythonProject4\venv\lib\site-packages\flask_socketio\__init__.py", line 641, in run raise RuntimeError('The Werkzeug web server is not ' RuntimeError: The Werkzeug web server is not designed to run in production. Pass allow_unsafe_werkzeug=True to the run() method to disable this error. 另一个输出* Serving Flask app 'flask-so' (lazy loading) * Environment: production WARNING: This is a development server. Do not use it in a production deployment. Use a production WSGI server instead. * Debug mode: off * Running on all addresses. WARNING: This is a development server. Do not use it in a production deployment. * Running on http://192.168.1.226:5000/ (Press CTRL+C to quit)
这个错误是由 Werkzeug Web 服务器引起的。Werkzeug Web 服务器是一个开发环境下使用的轻量级服务器,不建议在生产环境中使用。
根据你提供的信息,你正在尝试在生产环境中运行 Flask 应用程序,但是 Werkzeug Web 服务器会抛出一个错误,提示不建议在生产环境中使用它。
为了解决这个问题,你可以按照错误信息中提到的建议,在 `run()` 方法中传入 `allow_unsafe_werkzeug=True` 参数来禁用该错误。你可以修改代码如下:
```python
from flask import Flask
app = Flask(__name__)
@app.route('/')
def hello():
return 'Hello, World!'
if __name__ == '__main__':
app.run(host='0.0.0.0', port=7000, debug=False, allow_unsafe_werkzeug=True)
```
在这个示例中,我们将 `allow_unsafe_werkzeug=True` 作为参数传递给 `run()` 方法,以禁用该错误。
请注意,尽管可以禁用此错误,但在生产环境中,建议使用更稳定和安全的 Web 服务器,例如 Gunicorn 或 uWSGI 来运行 Flask 应用程序。
另外,在另一个输出中,你看到了一条警告信息,说明你当前正在使用 Flask 的开发服务器,该服务器不适合在生产环境中使用。警告建议你使用一个生产环境的 WSGI 服务器。
希望这可以帮助你解决问题!如果还有其他疑问,请随时提问。
s8 BME280_SPI_bus_read(u8 dev_addr, u8 reg_addr, u8 *reg_data, u8 cnt) { s32 iError=BME280_INIT_VALUE; u8 array[SPI_BUFFER_LEN]={0,}; u8 stringpos; /* For the SPI mode only 7 bits of register addresses are used. The MSB of register address is declared the bit what functionality it is read/write (read as 1/write as BME280_INIT_VALUE)*/ array[BME280_INIT_VALUE] = reg_addr|SPI_READ;/*read routine is initiated register address is mask with 0x80*/ /* * Please take the below function as your reference for * read the data using SPI communication * " IERROR = SPI_READ_WRITE_STRING(ARRAY, ARRAY, CNT+1)" * add your SPI read function here * iError is an return value of SPI read function * Please select your valid return value * In the driver SUCCESS defined as 0 * and FAILURE defined as -1 * Note : * This is a full duplex operation, * The first read data is discarded, for that extra write operation * have to be initiated. For that cnt+1 operation done in the SPI read * and write string function * For more information please refer data sheet SPI communication: */ for (stringpos = BME280_INIT_VALUE; stringpos < cnt; stringpos++) { *(reg_data + stringpos) = array[stringpos+BME280_DATA_INDEX]; } return (s8)iError; }
这段代码是用于通过SPI总线读取BME280传感器数据的SPI总线读取函数。
具体解析如下:
```c
s8 BME280_SPI_bus_read(u8 dev_addr, u8 reg_addr, u8 *reg_data, u8 cnt)
{
s32 iError = BME280_INIT_VALUE; // 用于存储错误码的变量
u8 array[SPI_BUFFER_LEN] = {0}; // 用于存储读取数据的数组
u8 stringpos;
// 在数组中存储读取操作的命令字节
array[BME280_INIT_VALUE] = reg_addr | SPI_READ;
/*
* 请在这里添加你的SPI读取函数
* iError 是SPI读取函数的返回值,根据你的实际情况选择合适的返回值
* 在该驱动程序中,成功定义为0,失败定义为-1
* 注意:
* 这是一个全双工操作,
* 第一个读取的数据被丢弃,所以需要额外的写操作
* 在SPI读写字符串函数中进行了cnt+1次操作
* 更多信息请参考BME280数据手册中的SPI通信部分:
*/
// 将读取到的数据存储到reg_data数组中
for (stringpos = BME280_INIT_VALUE; stringpos < cnt; stringpos++) {
*(reg_data + stringpos) = array[stringpos + BME280_DATA_INDEX];
}
return (s8)iError;
}
```
这段代码使用了一些宏定义和变量类型,其中s8是一个8位有符号整数类型,u8是一个8位无符号整数类型,s32是一个32位有符号整数类型。
这个函数的目的是通过SPI总线读取BME280传感器的数据。它接收设备地址、寄存器地址、用于存储读取数据的数组以及要读取数据的数量作为参数。
在这段代码中,首先在数组中存储读取操作的命令字节。然后,通过调用SPI读取函数(你需要根据你的实际情况添加实现),将读取到的数据存储到reg_data数组中。
请注意,这段代码只是一个示例,具体的实现可能会因你使用的SPI库和开发环境而有所不同。确保你正确配置了SPI总线,并根据你的具体需求和通信协议,编写和调用适合你的SPI读取函数。
阅读全文