mq135传感器stm32代码
时间: 2023-10-15 18:06:39 浏览: 282
在使用MQ135传感器与STM32的代码中,你可以使用模拟输入脚将AOUT引脚连接到STM32的AD转换输入脚。通过ADC将采集到的模拟信号转换为数字信号。在正常环境中,传感器输出电压值为参考电压的1V左右。当传感器检测到被测气体时,电压每升高0.1V,实际被测气体的浓度增加20ppm。根据这个参数,你可以在STM32中将测得的模拟量电压值转换为浓度值。
以下是一个基于MQ135传感器的简单示例代码:
```c
#include <stdio.h>
#include "stm32f10x.h"
void ADC_Configuration(void)
{
ADC_InitTypeDef ADC_InitStructure;
GPIO_InitTypeDef GPIO_InitStructure;
RCC_APB2PeriphClockCmd(RCC_APB2Periph_ADC1 | RCC_APB2Periph_GPIOA, ENABLE);
GPIO_InitStructure.GPIO_Pin = GPIO_Pin_1;
GPIO_InitStructure.GPIO_Mode = GPIO_Mode_AIN;
GPIO_Init(GPIOA, &GPIO_InitStructure);
ADC_DeInit(ADC1);
ADC_InitStructure.ADC_Mode = ADC_Mode_Independent;
ADC_InitStructure.ADC_ScanConvMode = DISABLE;
ADC_InitStructure.ADC_ContinuousConvMode = DISABLE;
ADC_InitStructure.ADC_ExternalTrigConv = ADC_ExternalTrigConv_None;
ADC_InitStructure.ADC_DataAlign = ADC_DataAlign_Right;
ADC_InitStructure.ADC_NbrOfChannel = 1;
ADC_Init(ADC1, &ADC_InitStructure);
ADC_Cmd(ADC1, ENABLE);
ADC_ResetCalibration(ADC1);
while(ADC_GetResetCalibrationStatus(ADC1));
ADC_StartCalibration(ADC1);
while(ADC_GetCalibrationStatus(ADC1));
}
uint16_t ADC_GetValue(void)
{
ADC_RegularChannelConfig(ADC1, ADC_Channel_1, 1, ADC_SampleTime_55Cycles5);
ADC_SoftwareStartConvCmd(ADC1, ENABLE);
while(!ADC_GetFlagStatus(ADC1, ADC_FLAG_EOC));
return ADC_GetConversionValue(ADC1);
}
int main(void)
{
uint16_t ADC_Value;
uint32_t MQ135_Concentration;
ADC_Configuration();
while(1)
{
ADC_Value = ADC_GetValue();
MQ135_Concentration = (ADC_Value * 100) / 5;
printf("MQ135 Concentration: %lu ppm\r\n", MQ135_Concentration);
// 延时或其他操作
}
}
```
阅读全文