(V
TERM
= 1.14V to 1.26V, V
DD18
= 1.7V to 1.9V, V
DD
= 0.95V to 1.05V or V
DD
= 1.14V to 1.26V, V
DDIO
= 1.7V to 3.6V, T
A
= -40°C to
+105°C, EP connected to PCB ground, typical values are at V
TERM
= 1.2V, V
DD18
= V
DDIO
= 1.8V, V
DD
= 1.0V, T
A
= +25°C, unless
otherwise noted.) (Note 1)
Note 1: Limits are 100% tested at T
A
= +105°C unless otherwise noted. Limits within the operating temperature range and
relevant supply voltage range are guaranteed by design and characterization.
Note 2: Not production tested. Guaranteed by design and characterization.
Note 3: Color bar pattern. Maximum supply currents are measured at indicated supply voltages. Typical supply currents are
measured at typical supply voltages specified in global conditions. For V
DD
supply current specifications with internal LDO
enabled (1.2V V
DD
range), typical V
DD
= 1.2V. For V
TERM
/V
DD
/V
DD18
supply current specifications, V
DDIO
= 1.8V/3.6V
typ/max. For V
TERM
/V
DD18
/V
DDIO
supply current specifications, V
DD
= 1V/1.05V typ/max.
Note 4: MFP pin speed programmed to fastest setting (TTS = 00). See Multifunction Pin Configuration for details regarding MFP
speed programming.
Note 5: C
LOAD
includes the low-frequency equivalent transmission line capacitance. The capacitance of Tx and Rx are assumed
to always be < 10pF. The distributed line capacitance can be up to 50pF for a transmission line with 2ns delay.
Note 6: Additional capacitance up to 60pF (D-PHY) or 90pF (C-PHY) at Rx termination center tap.
Note 7: Differential-mode and common-mode reflection coefficient are compliant with MIPI D-PHY V1.2 requirements over all
specified operating frequencies.
Note 8: Differential-mode and common-mode reflection coefficient are compliant with MIPI C-PHY V1.0 requirements over all
specified operating frequencies.
Note 9: For rates ≤ 1.5Gsps, t
R
and t
F
shall be ≤ min (0.4UI, t
RISE-FALL-MAX
)
Note 10: Measured at 50MHz. For V
DDIO
< 2.25V, speed group A and C, TTS = 00 and for V
DDIO
≥ 2.25V, speed group A and C,
TTS = 01. See Multifunction Pin Configuration for details regarding MFP speed programming.
AC Electrical Characteristics (continued)
www.maximintegrated.com
Maxim Integrated
│
19
MAX96712 Quad GMSL2 to CSI-2 Deserializer
with GMSL1 Compatibility
Maxim Confidential: LCFC
Released under NDA only