.\Output\Project.axf: Error: L6984E: AT section main.o(.ARM.__AT_0x20000A01) has required base address 0x20000a01 which is not aligned to section alignment 0x00000004. .\Output\Project.axf: Error: L6984E: AT section main.o(.ARM.__AT_0x20000A02) has required base address 0x20000a02 which is not aligned to section alignment 0x00000004. .\Output\Project.axf: Error: L6984E: AT section main.o(.ARM.__AT_0x20000A03) has required base address 0x20000a03 which is not aligned to section alignment 0x00000004. Not enough information to list image symbols. Not enough information to list the image map. Finished: 2 information, 0 warning and 3 error messages. ".\Output\Project.axf" - 3 Error(s), 10 Warning(s). Target not created
时间: 2024-04-18 22:26:35 浏览: 228
ARM_Imagefile_exe_mach_analysis.rar_ARM .a_arm_arm axf loading_
这个错误提示表明在链接过程中,发现了一AT(Address Table)节的地址不满足对齐要求。AT节用于指定数据或代码的地址,而对齐要求是确数据或代码按照指定的边界对齐的要求。
在你的代码中,AT节 `main.o(.ARM.__AT_0x20000A01)`、`main.o(.ARM.__AT_0x20000A02)` 和 `main.o(.ARM.__AT_0x20000A03)` 的基地址分别为 `0x20000a01`、`0x20000a02` 和 `0x20000a03`,但它们没有满足对齐要求 `0x00000004`。
要解决这个问题,你可以尝试以下几个步骤:
1. 检查你的代码中是否有对特定地址进行了手动分配的操作,特别是使用了 `__attribute__((section("name"), aligned(n)))` 这样的语法来指定地址和对齐方式。确认这些地址和对齐方式是否正确。
2. 确保你的代码中没有使用到了不支持对齐要求的数据类型或指令,例如使用了不对齐的数据访问指令。
3. 检查你的开发环境和编译器的设置,确保正确配置了对齐选项。例如,对于ARM编译器,可以使用 `-mno-unaligned-access` 选项来禁用不对齐访问。
4. 如果你的代码中使用了链接脚本(Linker Script),请检查脚本中是否有特殊的对齐要求,并根据需要进行调整。
如果以上步骤都不能解决问题,建议你仔细查阅编译器和链接器的文档,了解如何正确设置地址和对齐方式,或者请向相关技术支持寻求帮助。