7. CAMERA SUSPICION INPUT (No event programming required)
When unsealed, this input activates cameras in the areas which are assigned to the input.
When the input re-seals, the cameras continue to operate for the suspicion time.
Example: Suspicion button.
Note: Program suspicion time - Installer menu option 6 - Program Times.
8. DELAYED ACCESS/HUP AT NIGHT
Generates an alarm in access but will not report it until the delayed alarm timer has expired or a second delayed alarm is
activated.
Generates alarm in secure (reports night holdup).
Example: Holdup button on a counter where more than one holdup button is used.
Note: Program Delayed Alarm Time - Installer menu option 6 - Times.
9. RESET DELAYED INPUTS (No event programming required)
- Resets a delayed alarm type input if the input is sealed.
- Resets a delayed alarm type input if the delay timer is still running (and therefore a full alarm has not been activated).
- Stops cameras operating if the input is unsealed, but the delayed time will continue to run.
Example: Reset button for quick cancellation of alarm.
Note: Delayed input types are : 8, 11, 22, 40.
10. NOT USED
11. DELAYED ACCESS ALARM
Generates alarm in access but will not report it until the delayed alarm timer has expired or a second delayed alarm is
activated.
Example: Holdup button.
Note: Program Delayed Alarm Time - Installer menu option 6 - Times.
12. COURIER RESTART (No event programming)
Resets entry timers and restarts exit timers for any areas assigned to the input.
Example: Keyswitch inside a door.